Performance under Rated Conditions - All models
Parameter | Description |
Input Span Adjustment Range | No limits to adjustments within the maximum range except minimum span limit of 1 engineering unit |
Analog Output Digital Communications: |
Two-wire, 4 to 20 mA HART 7 protocol compliant Honeywell Digitally Enhanced (DE) protocol compliant |
Output Failure Modes | Honeywell Standard NAMUR NE 43 Compliance Normal Limits: 3.8 - 20.8 mA 3.8 - 20.5 mA Failure Mode: ≤ 3.6 mA and ≥ 21.5 mA ≤ 3.6 mA and ≥ 21.5 mA |
Output Accuracy | ±0.025 % span |
Supply Voltage Effect | 0.005 % span per volt. |
Transmitter Turn on Time (includes power up & test algorithms) | HART or DE: 6 sec. |
Analog Input | Stability: 0.05% of URL per year for 10 years Maximum Lead Wire Resistance: Thermocouples and millivolts: 25 ohms/leg RTD and ohms: 25 ohms/leg |
Response Time (delay + time constant) | Analog Output 500 mSec to reach 96% of final value with 0 seconds damping |
Damping Time Constant | HART: Adjustable from 0 to 102 seconds in 0.1 increments. Default: 0.50 seconds DE: Discrete values 0.0, 0.3, 0.7, 1.5, 3.1, 6.3, 12.7, 25.5, 51.1, 102.3 seconds. Default: 0.3 seconds |
Ambient Temperature Effect | Digital Accuracy For all RTD (except Pt200) and 500 ohmInput Types: 0.017 ohms/°C For RTD Pt200 and 2000 ohm Input Types: 0.034 ohms/C. Output D/A: 0.0045 % of span/°C |
Cold Junction Accuracy | ±0.5 °C |
Total Reference Accuracy | Digital Mode Digital Accuracy + C/J Accuracy (T/C input types only) Analog Mode (HART only) Digital Accuracy + Output D/A Accuracy + C/J Accuracy (T/C input types only) Example: Transmitter in Analog Mode with Pt100 sensor and 0 to 200°C range Total Reference Accuracy = 0.15 °C + (200 °C / 100%) * 0.025% = 0.20 °C |
Sensor Burnout | Burnout detection is user selectable. Upscale or down scale with critical status. |
Vibration Effect | Per IEC60770-1 field or pipeline, high vibration level (10-2000Hz: 0.21 displacement/3g max acceleration) |
Electromagnetic Compatibility | IEC 61326-3-1 |
Isolation | 2000 VDC (1400Vrms) Galvanic isolation between inputs and output. |
Stray Rejection | Common Mode AC (50 or 60 Hz): 120 dB (with maximum source impedance of 100 ohms) or ± 1 LSB (least significant bit) whichever is greater with line voltage applied. DC: 120 dB (with maximum source impedance of 50 ohms) or a ±1 LSB whichever is greater with 120 VDC applied. DC (to 1 KHz): 50 dB (with maximum source of impedance of 50 ohms) or ±1 LSB whichever is greater with 50 VAC applied. Normal Mode AC (50 or 60 Hz): 60 dB (with 100% span peak-to-peak maximum) |
EMC Compliance | EN 61326-1 and EN 61326-3-1 (SIL) |
Lightning Protection Option | Leakage Current: 10 uA max @ 42.4 VDC 85 °C Impulse rating: 8/20 uS 5000 A (>10 strikes) 10000 A (1 strike min.) 10/1000 uS 200 A (> 300 strikes) |
Parameter | Description |
Terminal Block and Module Housing | Lexan 500R (Polycarbonate, Glass Fiber Reinforced 10%) |
Connection Screws | M3 Nickel Plated Brass |