Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG)

Still deciding? Get samples of $ !
Request Sample
Product Details
Customization: Available
Certification: JIS, DIN, ANS, GB, CE, RoHS, ISO
Condition: Original New
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Fast Delivery
The supplier can deliver the goods within %s days
Quality Assurance
The supplier provides quality assurance
100% Finished Products Inspection
The supplier inspects 100% of finished products.
to see all verified strength labels (19)
Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG) pictures & photos
Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG) pictures & photos
Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG) pictures & photos
Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG) pictures & photos
Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG) pictures & photos
Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG) pictures & photos
  • Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG)
  • Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG)
  • Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG)
  • Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG)
  • Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG)
  • Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG)

Find Similar Products

Overview

Basic Info.

Measuring principle
FMCW/Synthesized Reflectometer
Measuring range
Up to 75 m (246 ft)
Measuring resolution
0.1 mm (0.001'')
Update time
0.1 sec
Weight
≈16 kg (35 lb)
Cable entries
3 x ¾” NPT *6 or 6 x M20 *7
Baud rate
1200 / 2400 / 4800 bps
Isolation voltage
> 1500 V
Common mode rejection
> 150 dB
Voltage levels
3.6V +/- 10%
Transport Package
Carton
Trademark
Honeywell

Product Description

Product Description
The SmartRadar FlexLine automatic tank gauge (ATG) combines innovative software algorithms with our proven planar antenna technology for the precision you need in custody transfer and inventory applications.
It provides consistent accuracy even under the toughest operating conditions, whether on domed roofs, bad stilling wells or when installed close to the tank shell. With the wireless option you can use it in the ISA100 wireless (IEC 62734) universal mesh network, seamlessly integrate it into any supervisory system, for better productivity, reliability, safety, security, and regulatory compliance. SmartRadar FlexLine is TÜV certified for use in safety rated loops up to SIL 3 as per IEC 61508, meets major recommendations such as API 2350 and is widely used in overfill protection loops to prevent overfill accidents. 

With a modular build, SmartRadar FlexLine, provides flexibility, letting you add options easily. Supporting multiple functions, it covers all tank gauging needs. The base Radar module measures the product level by the microwave unit and antenna. In addition six optional modules can be housed in the SmartRadar Flexline, to meet various I/0 requirements of tank gauging including HART and TRL/2 communication protocols. 

FlexLine offers best in class accuracies with no drift from ambient temperature effects. Xtreme Performance and High Performance models are certified as per OIML R85:2008 recommendations and can be used for country specific legal metrology approvals within all OIML member states. The Advanced 
Performance SmartRadar FlexLine is for use in inventory control measurement requirements as per API MPMS Ch. 3.1B recommendations.
This street light features high brightness, energy saving, environmental protection, and easy installation. It has a waterproof rating of IP67 and has passed CE certification. It is suitable for schools, parks, roadsides, factories, squares, etc. It has a warranty period of 3 years. Moreover, we can provide various styles to meet your needs.
ENRAF FIELD BUS–INTERFACING HOST
Advantages: 
Robust and proven communications that go the distance 
With hardly any special requirements on cable quality, the Bi-Phase Mark (BPM) is the current industry standard in tank gauging systems. The 2-wire BPM allows for cable lengths of at least 10 km (6 miles) and can be run over almost any existing cabling. It is suitable for communication between various models of tank gauges and Honeywell Enraf's Tank Inventory Management system and other supervisory systems through Communication Interface Units (CIUs). A high level of isolation is offered through a specially developed isolation transformer employed on both ends of the communication line.

- Uses existing infrastructure 

- Robust (unique lightning protection) 

- The de facto standard in tank farm automation 

- Covers long distances (more than 10 km/6 miles)
TRL/2 COMMUNICATION PROTOCOL
Advantages: 
Easy Expansion and Upgrades of obsolete tank gauging systems. 
Obsolete tank gauges and inventory systems are a common challenge. Poor performance or failures, challenges sourcing spares and lack of experienced maintenance can undermine efficiency, compliance efforts and safety. Honeywell's Enraf automatic tank gauges offer a cost effective solution to replace obsolete, underperforming gauges and systems without disruption to the process or existing infrastructure, by matching the historic TRL/2 Communication Protocol. Honeywell's Enraf SmartRadar FlexLine easily fit existing gauges' TRL/2 communication field bus, regardless of the gauge's manufacturer. With no need to replace the TRL/2 cabling, they also seamlessly integrate with the existing control room interfaces. 
- No rip-and-replace for Upgrade projects 

- No hot work required 

- Keep existing accessories like temperature sensors and HART™ based pressure transmitters 

- Use existing power and signal cabling to seamlessly integrate with existing field communication units
HART® AND ANALOG INPUT CONNECTIVITY MASTER
Advantages:
Seamless integration of HART® devices 
SmartRadar FlexLine supports all I.S. HART® compliant devices with a maximum of five connected devices per interface. When used in analogue mode, one process value (PV) can be measured. In combination with a capable HART® pressure transmitter, it can be used for HART® hybrid inventory measuring systems (HIMS).
The HART® connectivity can also be used for other tank application such as water bottom detection, temperature measurement and density. The module also supports roof immersion compensation with connected HART® sensors.
- Optimize your inventory by integrating temperature and pressure measurements 

- Install multiple HART® modules in one FlexLine gauge 

- Up to 5 connected HART® devices per interface 

- If used in combination with the VITO interface, three additional HART® 
devices can be connected 

- FlexLine can be used as a data concentrator for other functions such as ambient temperature measurements, Floating roof monitoring (FRM), fire detection and roof immersion compensation.
WIRELESS CONNECTIVITY
Advantages:
A new level in flexibility
With the integrated OneWireless solution, Honeywell Enraf gauges use the ISA100 wireless (IEC 62734) OneWireless universal mesh network to seamlessly integrate with any supervisory system, such as Entis, Experion PKS or other DCS. OneWireless helps optimize plant productivity and reliability, improve safety and security, and ensure regulatory compliance. The OneWireless option integrated in the FlexLine is simple to manage and efficient to operate, while the ISA100 wireless infrastructure allows for remote monitoring of installed equipment and supports full diagnostics.
- FlexLine can function as a "data concentrator" to transfer all tank information, including connected HART® devices, over wireless to the 
supervisory systems 

- Over-the-air key provisioning removing the need to climb on tank tops 
- The signal hopping feature within the FlexLine ensures continuous availability and reliability of communication.
- Reduce installation cost by 50% or more through wireless connectivity 
- Improve inventory accuracy by migrating to high-precision ATG without the need to run new cabling 

- Reduce operational costs by integrating wired and wireless devices in the same tank management software.
ALARM CONTACTS (DIGITAL OUTPUTS)
Advantages:
Digital outputs for alarm signaling or control functions 
Multiple relay contacts are offered for digital outputs associated with a wide range of common devices, such as relays, contactors, starters and two-position actuators. Contacts can be controlled remotely or switched automatically and linked to measured parameters, such as level, temperature, or pressure. The module provides four relay contacts that 
can be manually set to be normally open or normally closed and configured to be normally energized or normally de energized for failsafe behavior.
- Two different contact ratings 

- Two or four relays wired to connecting terminals 

- Ultimate flexibility in alarm signaling
SAFETY FUNCTIONS
Advantages:
Advantages:
SIL certified protection for safe operation
Certified by the TÜV for use in Safety Integrity Level (SIL) rated loops, FlexLine is a solution to prevent overfill and/ or dry run. With a Safe Failure Fraction of 97% it is suitable for use in SIL 2 safety loops and SIL 3 loops when used in redundant configuration. High diagnostic coverage allows the safety proof-test interval to be extended, bringing down operational costs. Dual redundancy with 2oo4D voting of the safety function automatically detects and reports failures in the safety circuitry, while allowing the gauge to continue to function as a safety device without interrupting the process. Higher availability means better efficiency. It's industry best internal diagnostic cycle time of <1 second, allows higher threshold settings, accommodating more storage space with bulk petroleum storage tanks.
- The device complies with the requirements of the relevant standards (Hardware safety integrity SIL 2 acc. to IEC 61508 and systematic capability SC 3 acc. to IEC 61508) and can be used in applications up to SIL 2 (HFT=0) resp. SIL 3 (HFT=1) acc. to IEC 61508 and IEC 61511 for the safety function maximum filling level detection. 
- Proof test interval of >10 years to reduce operational costs 
- 2oo4D configuration increases safety as well as availability 
- Internal diagnostic cycle time of < 1sec
- Internal diagnostic cycle time of < 1sec
 
- SIL certified Digital Outputs. 
- SIL certified 4-20ma Analog Output fully compliant with API Std 2350 
- Meets critical safety recommendations of having a high integrity, automatic operating overfill prevention system (or a number of such systems, as appropriate) that is physically and electrically separate and independent from the tank gauging system.
PLANAR ANTENNA TECHNOLOGY (PAT) - FREE SPACE & STILLING WELLS
Easy to fit on roof nozzles and for all sizes of stilling wells 
While the free space planar antenna is ideal in roof nozzles on cone roof tanks or dome roof tanks, Stilling well version of planar antenna are used for stilling well applications. 

Together with 6" and 8" free space antennas and different stem lengths, SmartRadar FlexLine provides easy answers for a range of different roof nozzles on cone roof and dome roof tanks. For tanks with stilling wells, the SmartRadar planar antenna comes in different sizes and covers 6", 8", 10", 12", 16", 20" and 24" stilling well sizes. 

Planar antennas are suitable for use in process pressure conditions up to 6 bar (87 psi) and can be used in extreme temperature conditions of as low as -200 °C (-328 °F) and up to +250 °C (+482 °F).
HIGH PRESSURE 4" HORN ANTENNA
Antenna for pressurized liquids up to 40 bar (580 psi) 
This horn antenna is developed for high pressure applications, such as LPG and chemical gasses. It is designed for spheres and bullets equipped with a 
4" Sch 10/40 stilling well or a 4" Sch10 insert pipe. Easy verification of radar level measurement is possible using verification pins. The high pressure tank 
separator provides both an approved and safe process seal. The Horn antenna is offered with an optional 1" ball valve or can also be installed on top 
of a 4" ball valve.
Specification
TECHNICAL SPECIFICATIONS
MEASURING PRINCIPLE
Measuring principle
FMCW/Synthesized Reflectometer
Signal processing
Fully digital using Enhanced Performance Signal Processing(EPSP)
Operating frequency
Xband (9.538 GHzto 10.561 GHz)R&TTE,FCC compliant
MEASURING SPECIFICATIONS
Measuring range
Upto 75m(246ft)
Instrument accuracy level
-Xtreme performance SmartRadar±0.4 mm(±0.016”)*1*2*3*4
-High performance SmartRadar±1 mm(±0.04”)*1*2*3
-Advanced performance SmartRadar±3 mm(±0.12”)*1
Measuring resolution
0.1mm(0.001'')
Update time
0.1 sec
MECHANICAL
Dimensions
217×319×379 mm(8.55”×12.55”×14.9")(H×W×L)*5
Weight
about 16 kg(35 Lb),depending on installed options and excluding antenna and tank separator
Cable entries
3x3/4”NPT*6or6×M20*7
PROCESS
Max.process pressure
-Planar(PAT)Antennas:upto 6 bar/0.6 MPa(87 psi)
-Horn Antennas:up to 40 bar/4 MPa(580 psi)
Process temperature range
-200℃ to+250℃(-328Fto+482F)*8,*9
PROCESS WETTED MATERIALS
Tank separator

Antenna materials
Stainless steel AISI 316(materialno.:1.4401)*10
-Planar(PAT)antennas:SS AISI 316(matno.:1.4401)and FEP
-High pressure horn antennas:SS AISI 316(mat.no.:1.4401)and PTFE
(in high pressure tankseparator)
-Ball valve (optionalwith horn antenna)stainless steel CF8M(mat no.:1.4408)
O-rings
FPM (in tank separator)*11
ENCLOSURE MATERIALS
Instrumenthousing
Cast aluminum alloy according to EN1706;AA A356 EN1706;AC-AISi7Mg0.3
Finish aluminum parts
Hard anodized according to MILA8625-E TypeII
Cover
Aluminum;coating:Polyurethane
O-rings
NBR 70
ENVIRONMENTAL
Ambienttemperature
-40 °C to+65°C (-40Fto+149F)
-50 °C to+75℃(-58Fto+167F)
Storage temperature
LEGAL METROLOGY 
Weights &Measures
NMi,PTB,BRML,UMI,LNE,DZM,ONML,W&MIndia,PAC,MIGAS,OIML,andseveralothers.Please check with factory for availability of local certificates with selected options.
FUNCTIONALSAFETY AND OVERFILL PREVENTION 
SILcertification
TÜV cerified for SIL2(single configuration,HFT=O)and SIL3(redundantconfiguration,HFT=1),
according to IEC61508&IEC61511
Overfillprotection
DIBt WHG,Corcon BVBA
EXPLOSION SAFETY APPROVALS
Explosion safety approvals/
certificates
-Ⅱ1/2GExd[iaGa]IIBT6Ga/Gb;acc.toATEXKEMA
-Exd [ia Ga]IIBT6 Ga/Gb;acc.to IECEx KEMA
– Ex d ia IIB T6; acc. to Kosha certificate
– Class I, Division 1, Groups C & D; acc. to FM
– ClassI,Division1,GroupsC&D;acc.toCSA
– Ex d [ia Ga] IIB T6 Ga/Gb; acc. to INMETRO TÜV
Otherapprovals/certificates
EXPLOSION SAFETY APPROVALS (CONTINUED)
Other approvals/certificates
Explosion proof: NEPSI, PESO (India), GOST-Rx Please check with factory for availability of local certificates with selected options.
Ingress protection
IP66/IP67 (NEMA 4X)
For Other explosion safety approvals/certificates and updates, please contact Honeywell representative.
ELECTRICAL
Power supplyPower supply
Autoselect 65 Vac to 240 Vac (+10% to -15%) 50/60 Hz and/or 24 Vdc to 65 Vdc (+10% to -15%)
Power rating
Typical 15 W; max. 23 W with all options
Maximum current (start-up)
Imax = 1.2 A
DATA COMMUNICATION
Enraf Field Bus (BPM)
Baud rate
1200 / 2400 / 4800 bps
Cable characteristics
2 wires, twisted pair, Rmax = 200 Ω / line, Cmax = 1 μF; cable length: 10 km (6 miles) or more *12
Isolation voltage
> 1500 V
Lightning protection
Full galvanic separation using isolation transformers
Common mode rejection
> 150 dB
Protocol
Standard Enraf Fieldbus (serial, ASCII GPU protocol)
Wireless Communications
Wireless communication
2400 to 2483.5 MHz (2.4 GHz) Industrial, Scientific and Medical (ISM) band, Modulation: DSSS – Discrete Sequential Spread Spectrum per FCC 15.247 / IEEE 802.15.4-2006
DSSS RF Transmitter power *13
– NA Selection (per FCC/IC): 125 mW (20.9 dBm) maximum transmit power not including an
tenna, or 400 mW (26.0 dBm) maximum EIRP including antenna, for USA and Canada locations 
– EU Selection (per RTTE/ETSI): 10 mW (10.0 dBm) maximum EIRP including antenna, for EU locations
Signal range (nominal) *14
– NA Selection (per FCC/IC): 
 ≈1800 m (5900 ft) with +4 dBi integral antenna 
 ≈1800 m (5900 ft) with +4 dBi integral antenna 
– EU Selection (per RTTE/ETSI): 
 ≈600 m (1970 ft) with +4 dBi integral antenna 
 ≈900 m (3000 ft) with +8 dBi integral antenna
Connectivity
– Published data: All process values available in the FlexLine 
– Publish Cycle Time: Configurable as 1, 5, 10 or 30 seconds 
– Protocol Tunnels: GPU and FlexConn
Wireless antennas
Integral: +4 dBi or +8 dBi omni directional monopole, with or without lightning surge arrestor *15
Wireless compliance
IEC62734 (ISA100 Wireless)
TRL/2 Communication Protocol TRL/2 Communication Protocol TRL/2 Communication Protocol
Protocol
Modbus RTU; Communication: TRL/2 100/90 KHz FSK
Baud rate
is 4800(+/-3%), 8 bits and 1 stop bit.
Cable
18 AWG (minimum) with shielded twisted pair, max 4 
kms with max 8 multi drop Gauge connections
Physical layer
Logic 1 is represented by 100kHz and Logic 
0 by 90khz:(+/-3%)
Voltage levels
3.6V +/- 10%.
Power rating
At 12V Nominal current drawn by TRL/2 module alone is 40mA(+/- 10%), [power con
sumption is 480mW(+/ 10%)]. The worst case current/power drawn with below mentioned 
conditions is 60mA
RS-232 GPU Protocol / Standard Modbus Protocol
Baud rate
1200 / 2400 / 4800 / 9600 / 19200 bps (configurable)
RS-232 GPU Protocol / Standard Modbus Protocol (CONTINUED)
Isolation voltage
> 600 V
Lightning protection
Opto-isolators
Protocol
Serial ASCII GPU protocol / Standard Modbus protocol (software switchable)
Max. instruments per line
1; point to point
Cable characteristics
3 wires, shielded and twisted, max. cable length: 15 m (50 ft)
RS-485 GPU Protocol / Standard Modbus Protocol
Baud rate
1200 / 2400 / 4800 / 9600 / 19200 bps (configurable)
Isolation voltage
> 600 V
Lightning protection
Opto-isolators
Protocol
Serial ASCII GPU protocol / Standard Modbus protocol (software switchable)
Max. instruments per line
32, multi point
Cabling
3 wires, shielded, twisted pair, signal ground, Rmax = 0.12 Ω / m, Cmax = 119 pF/m, 
Lmax = 1.45 mH, max. cable length: 1200 m (3900 ft)
HART® Slave – Multidrop and/or 4-20 mA
Protocol
Communications: HART® 6.2
Analog output loop (non-I.S.)
Active or Passive; selectable by jumper 
– Active: output voltage: 20V ±5% 
– Passive: minimum external supply voltage: 11.5 V maximum external supply voltage: 
30 V (55 V with serial resistor)
Accuracy
±0.1% of actual measurement
Burnout value
Low: 0 - 3.6 mA or High: 21 - 25 mA (configurable)
Cable characteristics
2 wires, shielded, twisted pair
SMARTVIEW DISPLAY – INTEGRATED AND/OR REMOTE
SmartView display
Refer to identification code for display options
Conn. with SmartView
Ex ia IIB ≈12 V
Cable characteristics for remote SmartView
4 wires, shielded, Cmax = 3 μF, Lmax = 0.48 mH, Rmax = 8.5 Ω (one SmartView connected) or Rmax = 4.7 Ω (two SmartViews connected)
OPTIONS (APPLIES ONLY IF OPTION SELECTED DURING GAUGE ORDERING)
Alarm Contact Options
2 x SPDT contact
0.5 A at 125 Vac or 0.3 A at 110 Vdc, Pmax = 30 W
2 x SPDT contact
2 A at 250 Vac or 3 A at 40 Vdc, Pmax = 750 W
4 x SPDT contact
2 x SPDT contact, 0.5 A at 125 Vac or 0.3 A at 110 Vdc, Pmax = 30 W and 
2 x SPDT contact, 3 A at 250 Vac or 3 A at 40 Vdc, Pmax = 750 W
Relay operation
– Normally Open/Normally Closed contact: selectable by jumper 
– Normally Energized / Normally De-energized: configurable by software setting 
– PV Monitor (any of the measured parameters, configurable by software setting) 
– Remote control (configurable by software setting)
SIL Safety Options
SIL Digital Output
1x SIL DO contact (1x SPDT contact, 2A at 250 Vac or 2 A at 40 Vdc, Pmax= 500 W) 
2x SIL DO contact (2x SPDT contact, 2A at 250 Vac or 2 A at 40 Vdc, Pmax= 500 W)
SIL Analog Output
SIL AO NAMUR NE43 compliant
SIL Digital Output + SIL Analog 
Output
SIL AO + 1 SIL DO + 1 SIL DO contact NAMUR NE43 compliant 
(1x SPDT contact, 2A at 250 Vac or 2 A at 40 Vdc, Pmax= 500 W) 
SIL AO + 2 SIL DO NAMUR NE43 compliant 
(2x SPDT contact, 2A at 250 Vac or 2 A at 40 Vdc, Pmax= 500 W)
VITO Input for Temperature and Water Probe
Communications
Proprietary HART®  (Ex-i)
Cable characteristics
2 wires, shielded, twisted pair, Cmax = 1 μF, Lmax = 9 mH, Rmax = 25 Ω / line
Accuracy
– Temperature measurement: ±0.1 °C (±0.18 °F) *17, *18 
– Water level measurement: ±2 mm (0.078") *17
Resolution
– Temperature measurement: 0.01 °C (0.01 °F) 
– Water level measurement: 0.1 mm (0.01")
Spot RTD Input
Configurations
– 3 wire or 4 wire RTD, one element or two elements *19 
– MPT or MRT up to 6 elements with 2 common ground wires *19
Cable characteristics
Shielded, Rmax = 100 Ω / line, Cmax = 1 μF, Lmax = 10.5 mH
Accuracy
±0.1 °C (±0.18 °F)
Resolution
0.01 °C (0.01 °F)
HART® Input
Configuration
Options 
– 5 HART® inputs and / or HIMS density calculation 
– VITO sensors and / or 3 HART® inputs 
– 3 HART® input, HIMS density calculation and VITO Sensors
Max. instrument per module
5 (digital) or 1 (analog)
Communications
HART® (revision 4)
Cable Characteristics
2 wires, shielded, twisted pair, Cmax - 1 μF, Lmax -9 mH, Rmax -25 Ω / line
Other Options
Flange or adapter plates
Adapter plates or flanges for different antennas are available
Notes:
*1 Under reference conditions 
*2 Certified as per OIML R85:2008 
*3 Legal Metrology (W&M) and Custody Transfer Applications 
*4 Selection "X" is additionally certified as per legal metrology requirements of Netherlands, France, Germany, Croatia, Bulgaria, Belgium, and for witness verification specify the authority (selection "X" in identification code) 
*5 Refer to the dimensional drawing shown in this document. HART®  is a registered trademark of the HART Communications Foundation 
*6 Exd only 
*7 Exe only 
*8 The temperature measured at process connection (Flange). 
*9 For cryogenic applications, the antenna is installed in the stilling well, above the tank roof, in an area with ambient temperature conditions. For cone roof / dome roof free space applications with a vapor temperature above +100 °C (+212 °F), the planar antenna shall be installed inside the roof nozzle above the tank roof. 
*10 Tank separators are available in free space (low pressure) and high pressure versions. 
*11 Special O-rings (Perlast® ) available for demanding chemical applications, part no.: U0990005. 
*12 Distances of more than 10 km possible depending on amount of field instruments and cabling topology. 
*13 For other countries and/or geographical area's refer to local and national radio legislations. 
*14 Specified distance are between field transmitter and infrastructure unit (Repeaters or Gateways), with clear line of sight. 
 Actual radio distances may be affected by local building and obstruction density closeness. 
*15 Lightening surge arrestors are recommended for lightening prone regions. 
*16 Depending upon the other options used and availability of slots for additional module, a twin safety function is possible offering independent relay contacts for prevention  of overfill and dry run (contact Honeywell representative.). 
*17 Under reference conditions. 
*18 With VITO temperature probe or Spot (Pt100) 
*19 Various generally available types of elements (RTD, MRT) can be selected.
Ordering Guide
Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG)
Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG)
Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG)
Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG)
Notes: 
Dark grey positions: Normal delivery Light grey positions: For lead time please consult factory or contact your local sales office 
*1 Add terminal count per choice. 
*2 Maximum sum of i.s. terminals = 10 
*3 Maximum sum of non i.s. terminals = 16 
*4 Maximum sum of slots = 7 
*5 Please make sure the wireless SmartRadar complies to local radio regulations 
*6 For witnessed verification please specify authority. Additional costs not included. 
*7 Migration Version is delivered without Antenna and Tank Separator 
*8 Position 6/7/8 if not used, use selection "None". 
*9 In pos 4, 5, 6, 7: each board type can only be selected twice except the RTD which can only be selected once. RS232 and RS485 counts as one type. VITO and HART counts as one type.
Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG)
Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG)
Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG)
Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG)
Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG)
Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG)
Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG)
Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG)
Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG)
Company Profile
BNSENS (Nanjing) Sensor Technology Co., Ltd. is located in Nanjing, China. It is a high-tech enterprise specializing in the development, manufacturing and trade of sensor products. The company has brought together a group of outstanding technical experts in various fields such as automation, electronics, machinery and computers. All employees of the company have college degrees or above. It adopts the world-class management and operation model and 6 sigma quality system. At present, the company's main products are pressure, liquid level, flow, current, switches, etc. The company's users are all over the country, and some products have been exported to Japan, South Korea and Southeast Asia.

Since its inception, the company has been based on the technical accumulation and management standards of American sensor giants. It is composed of senior engineers and managers who have served in multinational companies for many years, and has rapidly developed various pressure sensors, transmitters, liquid level, flow meters, pressure switches, digital meters, current sensors, proximity switches and other products. After years of unremitting efforts, it has become one of the leading suppliers in the domestic automation industry. Our pressure transmitters can achieve an accuracy of more than 3/10,000. The products have been widely used in oil, natural gas, electricity, chemical industry, metallurgy, building materials, food, light industry, environmental protection, aerospace, tap water, municipal and other industries.

It is a sensor science and technology innovation company that masters the core technology of MEMS chips. The company has a research and development center in Minnesota, USA. The leader is Dr. Pan Hanjin, a famous scientist in the sensor industry. Dr. Pan Hanjin has been deeply involved in the sensor industry for more than 20 years and is an expert in the sensor industry.

The company has a number of ASIC chips independently developed, which are widely used in industrial, automotive, home appliance and other markets.

BNSENS (Nanjing) Sensing Technology Co., Ltd. is a strategic partner of Honeywell in China. The two parties proposed a plan of East serving East and jointly developed several sensors specifically for the Chinese market. These sensors will be widely used in intelligent manufacturing, Internet of Things, artificial intelligence, and smart home fields. These sensors include: magnetic sensors, temperature sensors, humidity sensors, force sensors, fire water pressure sensors, equipment vibration sensors, human body status monitoring sensors, motion sensors, etc.
History of BNSENS Company:
BNSENS is a company focusing on sensors, instruments, and electronic components. We are a young company, founded in 1999, just 25 years old, and we are still growing.

1999: The company's first pressure sensor was launched, mainly for the petroleum and petrochemical industries.

2002: The company expanded its product line and launched temperature sensors

2005: Started producing high-precision pressure sensors for the test and measurement market

2006: Became an official authorized agent of Honeywell

2009: Introduced the Six Sigma management system, and the product qualification rate was greatly improved

2010: Became a supplier of Emerson

2011: We started selling SICK sensors

2014: Introduced the sensor production line from Germany, developed more industrial control sensors, and cooperated with TSMC

2015: Cooperated with Siemens in Vietnam

2017: The factory moved to Nanjing High-tech Zone

2019: Became a national high-tech enterprise in China

2023: We started selling products from Infineon and Rohm
2025: We started cooperating with Fluke

BNSENS,The Future Starts Here.
Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG)
Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG)
Honeywell Enraf Flexline Radar 990 SmartRadar FlexLine Automatic Tank Gauge (ATG)

Send your message to this supplier

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

People who viewed this also viewed