GENERAL | |||||||
Description | Field scanning and communication interface for tank inventory applications with optional embedded tank inventory calculation functionality. | ||||||
Application | For all applications requiring accurate and reliable process and inventory data, such as refineries, tank farms and terminals. Data is suitable for custody transfer, safe product transfer and tank farm operation. | ||||||
Intended Use | Control room equipment | ||||||
Legal Metrology and Custody Transfer | Compliant to API-standards as stated by approval and certification by notified bodies as NMI. | ||||||
FUNCTIONAL SPECIFICATION | |||||||
Tank Database | 80 tanks (one gauge per tank) 40 tanks (two gauges per tank) | ||||||
Redundancy | Hot standby, real-time synchronization (redundancy controlled by Entis Pro or modbus host) | ||||||
Supported Gauge Models | All GPU enabled tank gauges (such as 811, 813, 866, 854, 872, 873, 877, 894 , 990, 954) & Emerson TRL/2 | ||||||
Gauge Commands | •Lock test | •Unlock | •Block | ||||
•Freeze | •Calibrate (854, 894) | •Density dip | |||||
• Alarm test (SmartRadar) | • Water dip | ||||||
Tank Scanning | 6 field ports sequential and/or parallel, refresh rate 2-4 sec.1 | ||||||
Inventory Calculations | Conform API MPMS Ch. 12.1 | ||||||
Tank Capacity Tables (strapping tables) | Up to 5000 straps per tank, 400000 straps total | ||||||
Support API/ASTM Product Calculations | • ASTM D1250-80; conform Vol. X—Tables, 5, 6, 23, 24, 53, 54, 59, 60 and 59, 60 Commodities Product groups A, B, C & D • API MPMS Ch. 11.1 (2007; adj. to ASTM D1250-04 and IP-200)—Tables, 5, 6, 23, 24, 53, 54, 59, 60 and 59, 60; Product groups A, B, C, D • API MPMS Ch. 11.2.4 (GPATP-27)—Tables, 5, 6, 23, 24, 53, 54, 59, 60 and 59, 60; Product group E • ASTM D4311-83—Tables 1 and 2 • ASTM D4311-96—Table 1 • ASTM D4311-04—Tables 1 and 2 | ||||||
Available Gauge Data2 | •Product level | •Gauge status and alarms | |||||
•Product temperature | • Vapor temperature | ||||||
• Vapor pressure | • Ambient temperature | ||||||
• Water level | •Observed density (Servo, HTG, HIMS) | ||||||
• Temperature Profiles | •Density Profiles | ||||||
•Product pressure | |||||||
Available (Calculated) Inventory Data | • Volume (TOV, GOV, GSV, NSV) | •Mass (Liquid, vapor, total) | |||||
• Reference density | • Volume correction factor (VCF, CTL) | ||||||
• S&W, Vapor (4 types), DCF, TCF, manual CTL | • Volume derived flow | ||||||
FUNCTIONAL SPECIFICATION (CONT.) | |||||||
Clock & Time Synchronization | External using Entis Pro or Modbus host systems such as DCS | ||||||
Supported Engineering Units | Level | m, mm, ft, in, in/16 and ft-in-16 (fis) | |||||
Temperature | °C, °F | ||||||
Density | kg/m3, °API, lb/ft3, RD60/60, lb/USgal | ||||||
Pressure | kgf/cm2, kPa, psi(g), Pa | ||||||
Volume | m3, USgal, bbl, l(L) | ||||||
Mass/Weight | kg, lb, metric ton, long ton, US ton | ||||||
Flow | m3/min, m3/h, l/min, bbl/min, bbl/h, USgal/min, USgal/h, UKgal/h | ||||||
Available Tank Correction Methods | •CTSh3 •Floating Roof Weight | ||||||
Temperature and Density Profiles | • Temperature profiles - Periodic scanning of temperature profiles data up to 16 points from BPM and TRL/2 gauges and presentation in Modbus output (RTU and TCP/IP) based on configuration. • Density profiles - Density profiles data collection up to 10 density points from Honeywell Servo gauges and presentation in Modbus output (RTU and TCP/IP) based on user command. | ||||||
HOST CONNECTIVITY | |||||||
Serial Ports | 2x modbus serial (+ 4 additional ports by using optional slots) | ||||||
Supported Host Protocols | • Serial modbus (Slave) •CIU 858 emulation •CIU 880 Prime/Plus emulation (serial modbus) | ||||||
Ethernet/LAN | 3x Modbus TCP/IP ethernet (FTEA, FTEB and Office LAN) | ||||||
FIELD CONNECTIVITY | |||||||
Field Ports | 6x option slots (of which 4 ports can be used for serial host connectivity) | ||||||
Wireless Connectivity | ISA 100 via Honeywell WDM through TCP/IP to serial converters | ||||||
Available Option Boards | Enraf BPM fieldbus, Serial modbus (master) and Serial GPU input and TRL/2 Fieldbus | ||||||
COMPLIANCE & CERTIFICATIONS | |||||||
Electrical Safety | •IEC 61010-1:2010 (3rd edition) •EN 61010-1:2010 | ||||||
European Directives | CE: •2006/95/EC (Low voltage directive) •2004/108/EC (EMC) •CAN/CSA-C22.2 No. 61010-1-12 •UL Std. No. 61010-1 (3rd Edition) | ||||||
Self Monitoring & Diagnostics | Designed for compliance with NAMUR NE 107 | ||||||
Legal Metrology (Weight & Measures) | •NMI – Netherlands | ||||||
CIU 888 OPTION BOARD SPECIFICATIONS | |||
ENRAF BPM FIELD BUS CARD (POS 8 TO 13 = B) | |||
Physical Layer | 2-wire Bi-phase mark modulated (MIL-STD-1553) | ||
Supported Protocol(s) | Enraf BPM | ||
Typical No. Field Devices | 10-15, depending on cable spec and length | ||
Baud Rate | 1200/2400/4800 Baud | ||
Distance | 10 km or more depending on cable characteristics | ||
Cable Characteristics | 1 uF/200 Ohm max. | ||
Type of Galvanic Isolation | Transformer coupled with ground shield | ||
Galvanic Isolation | 1500 V | ||
TRL/2 FIELD BUS CARD | |||
Physical layer | Emerson TRL/2 Protocol | ||
Supported Protocol(s) | Modbus RTU | ||
Typical No. Field Devices | 8 | ||
Baud Rate | 4800 Baud | ||
Distance | 4 km | ||
Cable Characteristics | 18 AWG (minimum) with shielded twisted pair, max 4 kms with max 8 multi drop Gauge connections | ||
Type of Galvanic Isolation | Transformer coupled with ground shield | ||
Galvanic Isolation | 1500 V | ||
ENRAF SERIAL COMMUNICATION CARD (GPU MASTER (INPUT), MODBUS MASTER (INPUT) AND MODBUS SLAVE (HOST)) | |
Physical layer | 2-4 wire RS-485 or RS-232C |
Protocol(s) | •GPU Master (Field communication) •Modbus Master (Field communication) •Modbus Slave (Host communication) |
Baud Rate | 1200 up to 38400 Baud |
Type of Galvanic Isolation | Opto isolation |
Galvanic Isolation | 1500 V |
Number of Modbus Slave Devices (for modbus master field communications) | •32 modbus field devices (RS 485) multi-dropped. •1 modbus field device (RS232) •50 devices can be configured (If connected through a converter/concentrator) |
TECHNICAL SPECIFICATIONS—HARDWARE | |
ELECTRICAL | |
Power Supply | 100-240 Vac, auto ranging (-15% to +10%), 45-65 Hz |
Power Rating | Max. 60 VA (35 VA nominal) |
Nominal Start-Up Current | 60 mA (Fuse: 2A Slow Blow); Start up current is (inrush): 60mA @230V |
Over Voltage Category | II (EN60664-1 : 2007) |
Cooling System | 2 heat sinks with heat pipe design (no moving parts) |
Battery | Type 3V, 225mAh (for back-up system clock only—10 yrs. estimated life time) |
OPERATING SYSTEM | |
O/S | Linux Arch |
Memory | 4 GB Flash memory (upgradable) |
USER INTERFACE AND I/O | |
Front Panel Display | Backlight LCD color display (50 x 38 mm; 320 x 240 pixels) for status and diagnostics |
User Input | 6 switches with LED (ring of light) status indication |
Key Lock Switches | 2x (for configuration, resp. W&M sealing) |
Serial Ports | 2x non-isolated RS-232C |
Ethernet Ports | 5x 10/100 Mb on back side (future use) |
Service Ethernet Port | 1x behind front panel—DHCP enabled, auto sensing, 10/100 Mb |
ENVIRONMENTAL | |
Ambient Temperature | 0 °C to + 60 °C (32 °F to 140 °F) |
Storage Temperature | -20 °C to 85 °C (-4 °F to 185 °F) |
Enclosure Classification | Against mechanical impact IP 30 (NEMA 1) |
Humidity | 0 to 90% non-condensing |
EMC Class | CLASS A according to IEC61326 & OIML R85: 2008 |
MECHANICAL | |
Materials | •Enclosure: Acryl painted steel •Heat sinks (left and right side): Black anodized aluminum •Front panel: ABS/PPE |
Dimensions (WxHxD) | 400 x 93 x 283 mm (15¾ x 3¾ x 11¼ in.) |
Weight | ~ 7.5 kg (16.5 lb) (excluding option cards) |
Installation | Wall mounting, 19” rack or table top (see Accessoiries) |
Max. Load on Top (Table Top Use) | 10 kg (22.0 lb) |
AVAILABLE ACCESSORIES | |||
19" installation bracket | Part no. A0888904 | ||
Wall mounting bracket | Part no. A0888903 | ||
Set Ethernet Cables | Part no. A0888911 | ||
Set Ethernet cables | Part no. A0888911 | ||
1 SYNC link | Orange | 1 meter | |
2 FTE | Yellow/Green | 3 meter | |
1 LAN | Blue | 2 meter | |
1 Remote Access | Red | 3 meter | |
1 Service Port | Grey | 3 meter | |