Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Certification: | JIS, DIN, ANS, GB, CE, RoHS, ISO |
| Condition: | Original New |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
DATA COMMUNICATION | |
Honeywell Bi-phase mark(Pos 7=B) | |
Baud rate | 1200/2400 bps |
Cable characteristics | 2 wires,twisted pair,Rimax-200 Ohm/lne,Cmax-luF cable length 10km(Gmiles)or more*1 |
solationwoltage | >1,500V |
Lightrning protection | Full galanic separation via isolating transformers |
Protocol | Standard Honeywll fedbus (Serial, ASCII, GPU protocol) |
Commonmode rejection | >150dB |
TRL/2 Communication Protocol TRL/2 Communication Protocol TRL/2 Communication Protocol (Pos 7 = T) | |
Protocol | Modbus RTU; Commurication:TRL/2100/90 KHz FSK |
Baud rate | 4800,8 bits and 1 stop bIt. |
Lightrning protection | Opto-isolators |
Cabling | 18AWG (mirimum) with shieldled twisted pair, max 4km with max8 multi drop Gauge connections |
Ptysical layer | Logic l is represented by 100kHz and Logic 0 by 90khz: (+/-3%) |
Voltage levels | 3.6V+/-10%. |
Power rating | At 12V Nominal current drawn by TRL/2 module alone is 40mA(+/-10%). [power corsumption is 480mW(+/-10%).The worst case current/power drawn with belowmertioned concitions is 60mA. |
HART Slave-Multidrop and/or 4-20mA(Pos7-H) | |
Protocol | Commuricatiors:HART 7 |
Analog output loop (non-.S.) | Active or Passive; selectable byjumper -Active:output woltage:20V±5% -Passive:minimum exterml supplyvoltage:11.5V masimum external supplyvoltag:30V(55Vwithserial resistor) |
Accuracy | ±0.1% of actual measurement |
Cable characteristics | 2 wires, shielded,twistedpair |
ALARM CONTACT OPTIONS | |
Hardware alarms (1×SPDT) | 250 VAC, 2A(40 VDC,2A) |
Hardware alarms(2×SPDT) | 250 VAC, 2A(40 VDC,2A |
Relayoperation | -Normally Open/Normally Closedcontactselectable byjumper -Normally Energized/Normaly De-energizect configurable bysoftware setting -PV Morito (any of the measuredparameters,configurable bysoftware setting) -Remote control(configurable by softwaresetting) |
SIL 2/3SAFETYFUNCTIONSALARMCONTACTSOPTIONS | |
SIL Digital Output | 1×SIL DO contact(1×SPDT contact, 2A at 250Vac or 2A at 40Vdc. Pmax-500W) |
2×SIL DO contact(2×SPDT contact, 2A at 250 Vac or 2 A at 40 Vdc, Pmax-500w) | |
SIL Analog Output | SIL AO NAMUR NE43compliant |
SIL Digital Output+Analog Output | SIL AO+1SIL DO contact NAMUR NE43 compliant |
(1×SPDT contact , 2 A at 250Vac or 2A at 40 Vdc, Pmax=500W) | |
SIL AO +2 SIL DO contacts NAMUR NE43 compliant | |
(2×SPDT contact, 2 A at 250Vac or 2A at 40 Vdc, Pmax-500W) | |
INPUT | |
VITO Input forTemperature and Water Probe | |
Communications | Propdetary HART (Ex-i |
Cable characteristies | 2 wires,shielded, twisted pair,Cmax=1μF,Lmax=9mH,Rmax=25Ω/line |
Accuracy | - Temperature measurement:±0.1℃(±0.18°F)*2, *3 =Water level measurement:±2mm(0.078*+3 |
Raesolutiaon | =Temperature measurement:0.01℃(0.01°F) Water level measurement:0.1mm(0.01*) |
Spot RTD Input | |
Canfigurations | =3 wire or 4 wire RTD, one element or two elements*4 |
-MPTorMRT up to B dlementswith2cammonground wires 4 | |
Cable characteristies | Shielded, Rmax=100Ω/line, Cmax=1μF, Lmax=10.5mH |
Accuracy | ±0.1 °C (±0.18 °F) |
Resolutlion | 0.01℃ (0.01°F) |
HART*Input | |
Canfigurations | Options -5 HART#inputs and/arHIMS densitycaloulation VITO sensors and/or3 HART®inputs =3HART*input,HIMSdensitycalculation and VITO sensors |
Max.instruments per module | 5(digital)or1(analog) |
Communications | HART(revision4) |
Cable characteristies | 2wires, shladed, tulsted pair Cmax=1uF, Lmax=9mH, Rmax=252/line |
Other Optans | |
Cable entries | Adapters aralable to fit other sizes cable glands |
INSTRUMENT MEASURING SPECIFICATION | |
Level measuring range | |
Standard | 27m(88ft)Pos 18=A,B,C |
Extended | 37m(121ft)Pas 18-E,F |
40m(131ft)P=18=H, | |
45m(147ft)P≤18=K, | |
35m(115ft)(with measuring wire up to 150m(492ft))Pos18=M; | |
Forlonger ranges,please contact factory | |
Measuring accuracyleved | 40m(131.2ft):<±0.4mm(±0.016")*5; |
40m(131.2ft):OIML R85 certified(Pos 5×X); | |
45 meter with+-1 mm accuracy | |
last 35 meter with +-1 mm accuracy on 150m wire | |
Measuring accuracyinterface | <±2mm(±0.08*)*6 |
Measuring accuracytemperature | <±0.1℃(±0.18°F)*5 |
Sensltvity | <0.1mm(±0.004'')+5 |
Repeatablity | <0.1mm(±0.004'')+5 |
Density Measurement | |
Density measurement | With densty firmware (Pus20=D and density displacer (Pos19-EarF) |
Measuring accuracy servo density | <±3kg/m3(±0.19lb/ft3) |
MECHANICAL | |
FLange | See 'Identification Code' Pos14-16 |
Dimensions | See' Dimensional Drawing |
Welght | |
Mediumpressure verslon | 16kg(35 b) |
Chemical version | 21kg(46lb) |
High pressure version | 26 kg(57 lb) |
Cable entries | 4×3/4''NPT threaded (2*1.S.+2*non-1.S.) |
PROCESS | |
Operating pressure | |
Mand Cversions | Up to 6 bar/0.6 MPa(90 psi); Pos 14 |
H version | Up to 40 bar/4 MPa(600psi)(upto 25 bar/2.5 MPa in acc.to PED); Pos 14 |
Temperature | |
Max.processtemperature | +200℃(+392°F),drum housing must be kept below +65℃(+149°F)*7 |
Min.process temperature | -200℃(-328°F),drum housing mustbe kept above -40℃(-40F)*7 |
PROCESS WETTED MATERIALS | |
Drum compartment | Cast aluminum Int.reg.AAA356EN1706AC-AISi7Mg0.3;Pos14=A or M Stainless steelASTM A351,CF-8M,G-X6 CrNiMo 1810(1.4408);Pos 14=H orC |
Measuring drum, drum shaft | Stainless steel (1.4401) EN10088 AISI 316 |
Measuring wire | See 'Identification Code'; Pos 18 |
Magnetcap | Stainless steel(1.4401) EN10088 AISI 316 |
O-rings | Drum cover Silicone/FEP; others FPN(Viton); SpecialO-ring (Perlas) available for demanding chemical applications (such as Ammonia), part nr. S0854969 |
ENCLOSURE MATERIALS | |
Servo comp.and cover | All types castaluminum Int.reg.AAA356EN1706 AC-AISi7Mg0.3 |
Finish aluminum parts | Conforms to MIL-DTL-5541F |
ENVIRONMENTAL SAFETY | |
Ambient temperature | -40℃ to +65℃(-40°F to+149F) |
Storage temperature | -50℃ to +70℃(-58°Fto+158F) |
Protection class | IP66/IP67 according to EN 60529(NEMA4X) |
Safety | Explosion proof |
-II 1/2 G Exd IIB T6 Ga/Gb or Exde IIB T6 Ga/Gb or Exd[ia Ga] IIB T6 Ga/Gb or Ex de [ia Ga] IIB T6 Ga/Gb; acc.to ATEXKEMA -ClassI, Division 1, GroupC &D; acc.to FM | |
-Classl, Group C&D acc.to CSA certificate | |
Consult factory for other approvals and updates | |
ELECTRICAL | |
Power supply | Autoselect65 Vac to 240 Vac, 50/60Hz and/or 24Vdc to 65 Vdc |
Power rating | 11 Wmaxcontinuously |
MIGRATION OPTION | |
Migration kit 954(Pos4:Option M) | |
Migration Kit 954-Enraf Servo 854 ATG to Servo 954 hardware migration kit | |