Model Number | Description | ||
Commercial | |||
R8001M1050 | 50 in/lb Actuator NEMA 1 Enclosure | ||
R8001M1150 | 150 in/lb Actuator NEMA 1 Enclosure |
||
Industrial | |||
R8001M4050 | 50 in/lb Actuator NEMA 4 Enclosure | ||
R8001M4150 | 150 in/lb Actuator NEMA 4 Enclosure |
Actuator Options/Specs | Commercial Model | Industrial Model | |||||
50 in-lb R8001M1050 |
150 in-lb R8001M1150 |
50 in-lb R8001M4050 |
150 in-lb R8001M4150 |
||||
Communication | RS-485 non- isolated |
RS-485 non- isolated |
RS-485 Isolated | RS-485 Isolated | |||
Fault Annunciation | Generic Alarm | Generic Alarm | Yes | Yes | |||
Enhanced Data Logging | None | None | Yes | Yes | |||
Resolution | .2 Degree | .2 Degree | .1 Degree | .1 Degree | |||
Repeatability | .2 Degree | .2 Degree | .1 Degree | .1 Degree | |||
Duty Cycle (Act Availability) | 100% | 100% | 100% | 100% | |||
Opening Span | 90 Degrees | 90 Degrees | 90 Degrees | 90 Degrees | |||
90 Degree Travel Time | 30 sec | 30 sec | 15 sec max | 15 sec max | |||
Minimum Operating Temperature |
-28 °C (-18 °F) | -28 °C (-18 °F) | -40 °C (-40 °F) | -40 °C (-40 °F) | |||
Maximum Operating Temperature |
70 °C (158 °F) | 70 °C (158 °F) | 70 °C (158 °F) | 70 °C (158 °F) | |||
Temp Sensor | Yes; Alarm Only | Yes; Alarm Only | Yes; Alarm and Real Time Data |
Yes; Alarm and Real Time Data |
|||
Output | 1/2-in Keyed Output Shaft |
1/2-in Keyed Output Shaft |
1/2-in Keyed Output Shaft |
1/2-in Keyed Output Shaft |
|||
Keyed Connection | 1/8-in Square Key | 1/8-in Square Key | 1/8-in Square Key | 1/8-in Square Key | |||
Conduit Connections | 1/2-in Conduit Knockouts (2) (Shipped Closed) |
1/2-in Conduit Knockouts (2) (Shipped Closed) |
1/2-in Conduit Knockouts (2) (Shipped Closed) |
1/2-in Conduit Knockouts (2) (Shipped Closed) |
Type | Terminal | Description | Wiring |
PE (Protective Earth) | Chassis ground screw |
Chassis connection for mains power and shield/drain wires |
Follow local codes for safety earth installation. See Electrical installation section for shield drain installation instructions. |
DC power terminals | 24V+ | 24VDC positive terminal | Shielded twisted pair cable is recommended. A replaceable 2A fuse is provided on all actuators. Use a slow blow fuse if additional external fusing is desired. Required gauges are: Up to 80 ft: 24 AWG Up to 120 ft: 22 AWG Up to 500 ft: 16 AWG Up to 800 ft: 14 AWG Up to 1200 ft: 12 AWG |
24V- | 24VDC negative terminal | ||
Low voltage communication (Modbus over RS-485) Industrial models only: R8001M4050, R8001M4150 |
RS485 In+ | Isolated RS-485: positive | Shielded twisted pair cable with a separate common wire is recommended. See Electrical installation section for length limitations. Use 12-24 AWG wire. NOTE: Shield should be tied to chas- sis at Actuator side; do not connect at SLATE (control- ler) side. |
RS485 In- | Isolated RS-485: negative | ||
RS485COM | Isolated RS-485: common NOTE: Must be connected for reliable performance. |
||
Low voltage communication (Modbus over RS-485) Commercial models only: R8001M1050, R8001M1150 |
RS485 In+ | Non-isolated RS-485: positive | |
RS485 In- | Non-isolated RS-485: negative | ||
RS485COM | Non-isolated RS-485: common See note1 |