Honeywell Stg700 Smartline Gauge Pressure Sensor Stg73s -100kpa~350kpa

Product Details
Customization: Available
Type: Differential Pressure Transmitter
Structure Type: Diffused Silicon Pressure Transmitter
Still deciding? Get samples of US$ 560/Piece
Request Sample
Manufacturer/Factory & Trading Company
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (19)
  • Honeywell Stg700 Smartline Gauge Pressure Sensor Stg73s -100kpa~350kpa
  • Honeywell Stg700 Smartline Gauge Pressure Sensor Stg73s -100kpa~350kpa
  • Honeywell Stg700 Smartline Gauge Pressure Sensor Stg73s -100kpa~350kpa
  • Honeywell Stg700 Smartline Gauge Pressure Sensor Stg73s -100kpa~350kpa
  • Honeywell Stg700 Smartline Gauge Pressure Sensor Stg73s -100kpa~350kpa
  • Honeywell Stg700 Smartline Gauge Pressure Sensor Stg73s -100kpa~350kpa
Find Similar Products
  • Overview
  • Product Parameters
  • Dimension
Overview

Basic Info.

Model NO.
STG73S
Certification
CE
Wire Type
Two- Wire
Analog Output
4mA ~ 20 Ma
Digital Communications
Hart 7
Transmitter Turn on Time
2.5s
Place of Origin
Tianjin, China
Range
-100kpa~ 350kpa
Supply Voltage Effect
0.005% Span Per Volt

Product Description

Introduction

Part of the SmartLine® family of products, the STG700 and STG70L are suitable for monitoring, control and data acquisition featuring piezoresistive sensor technology combining pressure sensing with on-chip temperature compensation capabilities providing high accuracy, stability and performance over a wide range of application pressures and temperatures. The SmartLine family is also fully tested and compliant with Experion ® PKS providing the highest level of compatibility assurance and integration capabilities. SmartLine easily meets the most demanding application needs for pressure measurement applications.

 
Best in Class Features:
• Accuracies up to 0.065% of span.
• Stability up to 0.020% of URL per year for 10 years.
• Automatic temperature compensation.
• Rangeability up to 100:1.
• Response times as fast as 100ms .
• Easy to use and intuitive display capabilities.
• Intuitive External Zero, Span and configuration capability.
• Comprehensive on-board diagnostic capabilities.
• Integral Dual Seal design for safety based on
ANSI/NFPA 70-202 and ANSI/ISA 12.27.0.
• Full compliance to SIL 2/3 requirements.
• Modular design characteristics.
• Available with additional 4-year warranty.

Note: All data provided by Honeywell laboratories

Communications/Output Options:

• HART ® (version 7.0)

 

Unique Indication/Display Option
Standard LCD Display Features
• Modular (may be added or removed in the field).
• Supports HART protocol variant.
• 0, 90,180, & 270 degree position adjustments.
• Four configurable screens.
• Standard and custom measurement units available.
• Display calculated flow (square root) value in addition to analog output signal.
• 2 Lines 6 digits PV (9.95H x 4.20W mm) 8 Characters.
• Write protect Indication.
• Built-in Basic Device Configuration through Internal or External Buttons - Range/Engineering Unit/Loop Test /Loop Calibration/Zero /Span Setting.
• Multiple language capabilities (EN, RU).

 
Diagnostics
SmartLine transmitters all offer digitally accessible
diagnostics which aid in providing advanced warning of
possible failure events minimizing unplanned shutdowns,
providing lower overall operational costs.
 
System Integration
• SmartLine communications protocols all meet the most
current published standards for HART.
• All ST 700 units are Experion tested to provide the
highest level of compatibility assurance.
 
Configuration Tools
Integral Three Button Configuration Option
Suitable for all electrical and environmental requirements,
SmartLine offers the ability to configure the transmitter and
display via three externally accessible buttons when either
display option is selected. Zero/span capabilities are also
optionally available via these buttons with or without
selection of a display option.
Handheld Configuration
SmartLine transmitters feature two-way communication and
configuration capability between the operator and the
transmitter. All Honeywell transmitters are designed and
tested for compliance with the offered communication
protocols and are designed to operate with any standards
compliant handheld configuration device, such as Honeywell
Versatilis Configurator.
Personal Computer Configuration
On a personal computer or laptop, Honeywell Field Device
Manager (FDM) Software and FDM Express can be used for
managing HART device configurations.
Modular Design
To help contain maintenance & inventory costs, all ST 700
transmitters are modular in design supporting the user's
ability to replace meter bodies, standard displays or
electronic modules without affecting overall performance.
Each meter body is uniquely characterized to provide in
tolerance performance over a wide range of application
variations in temperature and pressure.
Modular Features
• Meter body replacement
• Add or remove standard displays
• Add or remove lightning protection (terminal connection) With no performance effects, Honeywell's unique modularity results in lower inventory needs and lower overall operating costs.
 
Product Parameters

Performance Under Rated Conditions - All Models

Parameter
Description
Analog Output
Digital Communications:
Two-wire, 4mA ~ 20 mA
HART7
HART Output Failure Modes
                             Honeywell Standard              NAMUR NE 43 Compliance
Normal Limits:             3.8 - 20.8 mA                             3.8 - 20.5 mA
Failure Mode:       ≤ 3.6 mA and  ≥ 21.0 mA           ≤ 3.6 mA and ≥ 21.0 mA
Supply Voltage Effect
0.005% span per volt.
Transmitter Turn on Time (includes power up & test algorithms)
2.5 seconds
Response Time (delay + time constant)
100ms
Damping Time Constant
Adjustable from 0 to 32 seconds in 0.1 increments. Default Value: 0.5 seconds
Vibration Effect:
Less than +/- 0.1% of URL w/o damping
Per IEC60770-1 field or pipeline, high vibration level (10-2000Hz: 0.21
displacement/3g max acceleration)
Electromagnetic Compatibility
IEC 61326-3-1
Lightning Protection Option
Leakage Current: 10uA max @ 42.4VDC 93C
Impulse rating: 8/20us 5000A (>10 strikes) 10000A (1 strike min.)
10/1000us 200A (> 300 strikes)
 
Materials Specifications (see model selection guide for availability/restrictions with various models)
Parameter
Description
Barrier Diaphragms Material
STG700 Dual Head: 316L SS, Hastelloy® C-2762
STG700 Inline: 316L SS, Hastelloy® C-2762
Process Head Material
STG700 Dual Head: Carbon Steel (Zinc Plated)5 , 316 SS4 , Hastelloy® C-2766
STG700 Inline: 316L SS, Hastelloy® C-2766
Vent/Drain Valves & Plugs 1
STG700 Dual Head:316 SS4 , Hastelloy® C-2762
STG700 Inline: N/A
Head Gaskets
STG700 Dual Head: Glass-filled PTFE standard. Viton® and graphite are optional.
STG700 Inline: N/A
Meter Body Bolting
STG700 Dual Head: Carbon Steel (Zinc plated) standard. Options include 316 SS,
NACE A286 SS bolts and nuts or NACE A286 SS bolts and 304 SS nuts, and Super Duplex.
STG700 Inline: N/A
Mounting Bracket
Carbon Steel (Zinc-plated) or 304 or 316 Stainless Steel, See Figures 3 & 4
Fill Fluid
Silicone, CTFE
Electronic Housing
Pure Polyester Powder Coated Low Copper (<0.4%) - Aluminum.
Meets Type 4X / IP66 / IP67. All stainless-steel housing is optional.
Cover O ring material: Silicone.
Process Connections
STG700 Dual Head: ½ -inch NPT(female)
STG700 Inline: ½ -inch NPT(female), ½ -inch NPT male, 9/16 Aminco, G½ -B Male Thread
Wiring
Accepts up to 16 AWG (1.5 mm diameter).
Dimensions
See Figure 3 and Figure 4
Net Weight
STG700 Dual Head: 8.3 pounds (3.8 Kg). STG700 Inline: 3.6 pounds (1.6 Kg) with Aluminum Housing
1 Vent/Drains are sealed with Teflon®
2 Hastelloy® C-276 or UNS N10276
4 Supplied as 316 SS or as Grade CF8M, the casting equivalent of 316 SS.
5 Carbon Steel heads are zinc-plated and not recommended for water service due to hydrogen migration. For that service, use 316
stainless steel wetted Process Heads.
6 Hastelloy® C-276 or UNS N10276. Supplied as indicated or as Grade CW12MW, the casting equivalent of Hastelloy® C-276

 
Communications Protocols & Diagnostics
 
HART Protocol
Version: HART 7
 
Standard Diagnostics
ST 700 top level diagnostics are reported as either critical or non-critical and readable via the DD/DTM/FDI tools or Standard
integral display. Some of the diagnostics are listed below:
Critical Diagnostics
• Electronics Module Fault.
• Meter body Memory Corruption.
• Config Data Corruption.
• Electronics Module Diagnostics Failure.
• Meter body Critical Failure.
• Sensor Communication Timeout.
 
Non-Critical Diagnostics
• Display Failure.
• Electronics Module Comm Failure.
• Meter body Excess Correct.
• Sensor Over Temperature.
• Fixed Current Mode.
• PV Out of Range.
• No DAC Compensation.
Refer to the product user manual for comprehensive list of diagnostics and details.



Honeywell Stg700 Smartline Gauge Pressure Sensor Stg73s -100kpa~350kpa


 
Dimension

 

Honeywell Stg700 Smartline Gauge Pressure Sensor Stg73s -100kpa~350kpa
Honeywell Stg700 Smartline Gauge Pressure Sensor Stg73s -100kpa~350kpa


Honeywell Stg700 Smartline Gauge Pressure Sensor Stg73s -100kpa~350kpaHoneywell Stg700 Smartline Gauge Pressure Sensor Stg73s -100kpa~350kpa

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier