The NFS2-640 intelligent Fire Alarm Control Panel is part of the ONYX® Series of Fire Alarm Controls from NOTIFIER.
In stand-alone or network configurations, ONYX Series products meet virtually every application requirement.
The NFS2-640's modular design makes system planning easier. The panel can be configured with just a few devices for small building applications, or networked with many devices to protect a large campus or a high-rise office block. Simply add additional peripheral equipment to suit the application.
A host of other options are available, including single- or multichannel voice; firefighter's telephone; LED, LCD, or PC-based graphic annunciators; networking; advanced detection products for challenging environments; wireless fire protection; and many additional options.
NOTE: Unless called out with a version-specific "E" at the end of the part number, "NFS2-640" refers to models NFS2-640 and NFS2-640E; similarly, "CPU2-640" refers to models CPU2-640 and CPU2-640E.
ONYX® Series panels integrate with the Connected Life Safety Services (CLSS) platform through the CLSS Gateway, providing
connectivity to central station, cloud, and mobile applications. (See HON-62034.) This cloud-based functionality provides reliable protection and remote monitoring of the system, reduced manual data entry, and reporting
• Certified for seismic applications when used with the appropriate seismic mounting kit.
• Approved for Marine applications when used with listed compatible equipment. See DN-60688.
• One, expandable to two, isolated intelligent Signaling Line Circuit (SLC) Class A, B, or X.
• Wireless fire protection using SWIFT Smart Wireless Integrated Fire Technology. See DN-60820.
• Up to 159 detectors and 159 modules per SLC; 318 devices per loop/636 per FACP or network node.
- Detectors can be any mix of photo, thermal, or multi-sensor; wireless detectors are available for use with the FWSG(A).
- Modules include addressable pull stations, normally open contact devices, two-wire smoke detectors, notification, or relay;wireless modules are available for use with the FWSG(A).
• Standard 80-character display, 640-character large display (NCA-2), or display-less (a node on a network).
• Network options:
- High-speed network for up to 200 nodes (N16e/x, NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCD, NCA-2, DVC-EM,
ONYXWorks, NFS-3030, NFS-640, and NCA).
- Standard network for up to 103 nodes (N16e/x, NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCD, NCA-2, DVC-EM, ONYXWorks, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP- 300/400, AFP-1010, and AM2020). Up to 54 nodes when DVCEM is used in network paging.
• 6.0 A switch mode power supply with four Class A/B built-in Notification Appliance Circuits (NAC). Selectable System Sensor,
Wheelock, or Gentex strobe synchronization.
• Built-in Alarm, Trouble, Security, and Supervisory relays.
• Optional cloud connectivity for remote off site monitoring through CLSS (see HON-62034)
• Monitor multiple buildings through one off-campus central station, and report through the CLSS Gateway
• Optional remote programing through CLSS
• Field-programmable on panel or on PC.
• VeriFire® Tools online or offline programming utility. Upload/ Download, save, store, check, compare, and simulate panel databases. Upgrade panel firmware.
• Autoprogramming and Walk Test reports.
• Multiple central station communication options:
- Standard UDACT
- Internet
- Internet/GSM
• 80-character remote annunciators (up to 32).
• EIA-485 annunciators, including custom graphics.
• Printer interface (80-column and 40-column printers).
• History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm-only file.
• Alarm Verification selection per point, with automatic counter.
• Presignal/Positive Alarm Sequence (PAS).
• Silence inhibit and Auto Silence timer options.
• March time/temporal/California two-stage coding/strobe synchronization.
• Full QWERTY keypad.
• Battery charger supports 18 - 200 AH batteries.
• Non-alarm points for lower priority functions.
• Remote ACK/Signal Silence/System Reset/Drill using monitor modules.
• Automatic time control functions, with holiday exceptions.
• Surface Mount Technology (SMT) electronics.
• Extensive, built-in transient protection.
• Powerful Boolean logic equations.
• Support for SCS Series smoke control system in HVAC mode.
NCA-2 AS PRIMARY DISPLAY
• Backlit, 640-character display.
• Supports SCS Series smoke control system in FSCS mode when SCS is connected to the NCA-2 used as primary display.
• Supports DVC digital audio loop.
• Printer and CRT EIA-232 ports.
• EIA-485 annunciator and terminal mode ports.
• Alarm, Trouble, Supervisory, and Security relays.
SWIFT WIRELESS
• Self-healing mesh wireless protocol.
• Each SWIFT Gateway supports up to 49 SWIFT devices.
• Up to 4 wireless gateways can be installed with overlapping network coverage.
RELEASING FEATURES
• Ten independent hazards.
• Sophisticated cross-zone (three options).
• Delay timer and Discharge timers (adjustable).
• Abort (four options).
• Low-pressure CO2 listed.
DIGITAL VOICE AND TELEPHONE FEATURES
• Up to eight channels of digital audio.
• 35, 50, 75, and 100/125 watt digital amplifiers (DAA2/DAX series and DS series; NCA-2/C required as primary display).
• Solid-state digital message generation.
• Firefighter telephone option.
• 30- to 120-watt high-efficiency amplifiers (AA Series).
• Backup tone generator and amplifier option.
• NFS2-640 can also integrate with the FirstCommand® Emergency Communications System. See DN-60772.
HIGH-EFFICIENCY OFFLINE SWITCHING 3.0 A POWER SUPPLY (6.0 A IN ALARM)
• 120 VAC (NFS2-640); 240 VAC (NFS2-640E).
• Displays battery current/voltage on panel (with display).
FLASHSCAN® INTELLIGENT FEATURES
• Polls up to 318 devices in less than two seconds.
• Activates up to 159 outputs in less than five seconds.
• Multicolor LEDs blink device address during Walk Test.
• Fully digital, high-precision protocol (U.S. Patent 5,539,389).
• Manual sensitivity adjustment - up to nine levels.
• Pre-alarm ONYX intelligent sensing - up to nine levels.
• Day/Night automatic sensitivity adjustment.
• Sensitivity windows:
- Photo - 0.5 to 2.35%/foot obscuration.
- High-Sensitivity Photoelectric (VIEW®) - Open Air Protection (0.5% - 2.0%/ft. obscuration), Special Applications (0.02%- 0.5%/ft. obscuration)
- Multi-Criteria Detector - Open Air Protection (2.52-3.89%/ft. obscuration), Special Applications (1.13-2.52%/ft. obscuration)
• Drift compensation (U.S. Patent 5,764,142).
• Degraded mode: In the unlikely event that the CPU2-640 microprocessor fails, FlashScan detectors revert to degraded operation
and can activate the CPU2-640 NAC circuits and alarm relay. Each of the four built-in panel circuits includes a Disable/Enable switch for this feature.
MAIN SYSTEM COMPONENTS
CPU2-640: Central processing unit (CPU) with integral 3.0 A (6.0 A in alarm) power supply for an NFS2-640 system. Includes control panel factory-mounted on a chassis; one Signaling Line Circuit expandable to two; documentation kit. Order one per system or as necessary (up to 103 network nodes) on a network system. (Non-English versions also available: CPU2-640-FR, CPU2-640-PO, CPU2-640-SP.)
CPU2-640E: Same as CPU2-640 but requires 240 VAC, 1.5 A, (3.0 A in alarm). (Non-English versions also available: CPU2-640E-PO, CPU2-640E-SP.)
ELECTRICAL SPECIFICATIONS
• Primary input power:
- CPU2-640 board: 120 VAC, 50/60 Hz, 5.0 A.
- CPU2-640E board: 220/240 VAC, 50/60 Hz, 2.5 A.
• Current draw (standby/alarm):
- CPU2-640(E) board: 0.250 A. Add 0.035 A for each NAC in use.
- KDM-R2: 0.100 A.
- LEM-320: 0.100 A.
• Total output 24 V power: 6.0 A in alarm.
NOTE: The power supply has a total of 6.0 A. of available power. This is shared by all internal circuits. See Installation Manual for a complete current draw calculation sheet.
• Standard notification circuits (4): 1.5 A each.
• Resettable regulated 24V power: 1.25 A.
• Two non-resettable regulated 24V power outputs:
- 1.25 A.
- 0.50 A.
• Non-resettable 5V power: 0.15 A.
• Battery charger range: 18 AH - 200 AH. Use separate cabinet for batteries over 26 AH.
• Float rate: 27.6 V.