sensitivity, temperature effects and accuracy errors (which include nonlinearity, repeatability and hysteresis) using an on-board Application Specific Integrated Circuit (ASIC). Calibrated output values for pressure are updated at approximately 1 kHz for analog and 2 kHz for digital. All products are designed and manufactured according to ISO 9001 standards.
Tech Specifications
Description |
Product Attribute |
Manufacturer |
Honeywell |
Product Category |
Board Mount Pressure Sensors |
Pressure Type |
Gage |
Operating Pressure |
0 psi to 30 psi |
Accuracy |
0.25 % |
Output Type |
SPI |
Mounting Style |
Leadless SMT |
Operating Supply Voltage |
5.0 V |
Port Type |
Single Axial Barbless |
Resolution |
12 bit |
Package / Case |
Leadless SMT |
Minimum Operating Temperature |
- 40 °C |
Maximum Operating Temperature |
+ 85 °C |
Series |
ABP |
Product Type |
Board Mount Pressure Sensors |
Subcategory |
Sensors |
1 Sensors are either 3.3 Vdc or 5.0 Vdc based on the catalog listing selected.
2 Ratiometricity of the sensor (the ability of the device output to scale to the supply voltage) is achieved within the specified operating voltage.
3 The sensor is not reverse polarity protected. Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure.
4 Operating temperature range: The temperature range over which the sensor will produce an output proportional to pressure.
5 Compensated temperature range: The temperature range over which the sensor will produce an output proportional to pressure within the specified performance limits.
6 Temperature output option: Typical temperature output error over the compensated temperature range of 0°C to 50°C. Operation in
Sleep Mode may affect temperature output error depending on duty cycle.
7 Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range. Includes all errors due to offset, full scale span, pressure non-linearity, pressure hysteresis, repeatability, thermal effect on offset, thermal effect on span, and thermal hysteresis.
8 Full Scale Span (FSS): The algebraic difference between the output signal measured at the maximum (Pmax.) and minimum (Pmin.) limits of the pressure range. (See Figure 2.)
9 Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at 25°C [77°F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability.