Honeywell EC7890B1010 Relay Module 7800 SERIES EC7890A,B; RM7890A,B,C Relay Module

Product Details
Customization: Available
Function: Automatic Control, Protection, Monitoring, Measurement
Certification: RoHS, CCC, ISO: 9001, CE
Still deciding? Get samples of $ !
Request Sample
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Fast Delivery
The supplier can deliver the goods within 30 days
Quality Assurance
The supplier provides quality assurance
100% Finished Products Inspection
The supplier inspects 100% of finished products.
to see all verified strength labels (19)
  • Honeywell EC7890B1010 Relay Module 7800 SERIES EC7890A,B; RM7890A,B,C Relay Module
  • Honeywell EC7890B1010 Relay Module 7800 SERIES EC7890A,B; RM7890A,B,C Relay Module
  • Honeywell EC7890B1010 Relay Module 7800 SERIES EC7890A,B; RM7890A,B,C Relay Module
  • Honeywell EC7890B1010 Relay Module 7800 SERIES EC7890A,B; RM7890A,B,C Relay Module
  • Honeywell EC7890B1010 Relay Module 7800 SERIES EC7890A,B; RM7890A,B,C Relay Module
  • Honeywell EC7890B1010 Relay Module 7800 SERIES EC7890A,B; RM7890A,B,C Relay Module
Find Similar Products

Basic Info.

Model NO.
EC7890B1010
Condition
Original New
Manufacturer
Honeywell
Part Number
EC7890B1010
Ambient Temperature
-40 °C to 60 °C
Maximum Humidity
85 %rh
Transport Package
Carton
Trademark
Honeywell
Origin
Mexico

Product Description

The Honeywell EC7890A,B/RM7890 is a microprocessor based integrated burner control for automatically fired gas, oil or combination fuel single burner applications. The EC/RM7890 system consists of the Relay Module, Subbase and Amplifier. Options include Keyboard Display Module (KDM), Personal Computer Interface, Data ControlBusô Module, Remote Display Module, First-Out Expanded Annunciator and COMBUSTION SYSTEM MANAGER Software.
The EC/RM7890 is programmed to provide a level of safety, functional capability and features beyond the capacity of conventional controls.
Functions provided by the EC/RM7890 include automatic burner sequencing, flame supervision, system status indication, system or self-diagnostics and troubleshooting

FEATURES
• Safety features:
   - Closed loop logic test.
   - Dynamic AMPLI-CHECK.
   - Dynamic input check.
   - Dynamic safety relay test.
   - Dynamic self-check logic.
   - Expanded safe-start check.
   - Internal hardware status monitoring.
   - Tamper resistant timing and logic.
• Access for external electrical voltage checks.
• Application flexibility. ï Communication interface capability (optional).
• Dependable, long-term operation provided by microcomputer technology.
• First-out annunciation and system diagnostics are provided by a 2 row by 20 column Vacuum Fluorescent Display (VFD) located on the optional Keyboard Display Module.
• First-out expanded annunciation with 26 Light Emitting Diodes (LEDs) for limits and interlocks (optional). ï Five (LEDs) for sequence information. (See Fig. 1.)
• Interchangeable plug-in flame amplifiers.
• Local or remote annunciation of RM7890 operation and fault information (optional).
• Nonvolatile memory; EC/RM7890 retains history files and sequencing status after loss of power.
• Provides 0.8 or 3.0 second FFRT, depending on amplifier selected. EC7890A1029, EC7890B1028 are 1.0 or 2.0 second FFRT. ï Remote reset (optional).
• Report generation (optional).
• Selectable relight (0.8 second FFRT amplifier only) or lockout on loss of flame.
• Shutter drive output (EC/RM7890B).
• Burner controller data (optional):
   - Expanded annunciator status.
   - Flame signal strength.
   - Hold status.
   - Lockout/alarm status.
   - Sequence status.
   - Sequence time.
   - Total cycles of operation.
   - Total hours of operation.
   - Fault history providing the six most recent faults:
• Cycles of operation at the time of the fault.
• Expanded annunciator data at the time of the fault. ï fault message and code.
• Hours of operation at the time of the fault.
• Sequence status at the time of the fault.
•Sequence time at the time of the fault.
   - Diagnostic information:

• Device type.
• Flame amplifier type.
• Flame failure response time.
• Manufacturing code.
• On/Off status of all digital inputs and outputs.
• Software revision and version of RM7890 and optional Keyboard Display Module.
• Status of configuration jumpers.


Table 1. Sequence Timing For Normal Operation.
Device Initiate Standby Pilot Flame Establishing Period (PFEP) Run
EC7890A/RM7890A 10 seconds * 4 or 10 seconds *
EC7890B/RM7890B 10 seconds * 4 or 10 seconds *
RM7890C 10 seconds * Standing Pilot *
*STANDBY and RUN can be an infinite time period.
 
Table 2. Terminal Ratings.
Terminal Number Description Ratings (RM7890A,B,C) Ratings (EC7890A,B)
G Flame Sensor Ground - -
Earth G Earth Grounda - -
L2(N) Line Voltage Common - -
Line Voltage Supply (L1) 120 Vac (+10%/-15%), 50 or 60 Hz
(±10%)b
220 to 240 Vac (+10%/-15%), 50 or
60 Hz (±10%)
Alarm 120 Vac, 1A pilot duty. 220 to 240 Vac, 1A pilot duty.
Unused - -
Burner Control and Limits 120 Vac, 8A run, 43A inrush. 220 to 240 Vac, 5A (maximum)
Unused - -
Pilot Valve/Ignition 120 Vacc 220 to 240 Vac,
4A at P.F. = 0.5, 20A inrush
Main Fuel Valve 120 Vacc 220 to 240 Vac,
4A at P.F. = 0.5, 20A inrush
10  Ignition 120 Vac, 4.5A ignition.d 220 to 240 Vac, 4A at P.F. + 0.2
F(11) Flame Sensor 60 to 220 Vac, current limited. 60 to 220 Vac, current limited.
12 to 21 Unused - -
22  Shutter 120 Vac, 0.5A (RM7890B). 220 to 240 Vac (EC7890B only)d
a The RM7890 must have an earth ground providing a connection between the subbase and the control panel or the equipment.
The earth ground wire must be capable of conducting the current to blow the 15A fuse (or breaker) in event of an internal short
circuit. The RM7890 needs a low impedance ground connection to the equipment frame which, in turn, needs a low impedance
connection to earth ground. For a ground path to be low impedance at RF frequencies, the connection must be made with minimum length conductors having maximum surface areas. Wide straps or brackets rather than leadwires are preferred. Be careful to verify that mechanically tightened joints along the ground path, such as pipe or conduit threads or surfaces held together
with fasteners, are free of nonconductive coatings and are protected against mating surface corrosion.
b 2000 VA maximum connected load to RM7890 Assembly.
c See Tables 3 and 4 for device load combinations.
d Requires 220-240 to 120 Vac, 10 VA minimum stepdown transformer to drive shutter.
 
Table 3. Combinations for terminals 8, 9, and 10.
Combination Number Pilot Fuel
8
Main
9
Ignition
10
C F No Load
B F No Load
No Load F No Load
F F A
No Load F A
D F A
D D A
No Load D A
 
Table 4. Composition of each combination.
A. B. C. D. F.
4.5A ignition 50 VA Pilot Duty
plus 4.5A Ignition.
180 VA Ignition plus Motor
valves with:
660 VA inrush, 360 VA
open, 250 VA hold.
2A Pilot Duty. 65 VA Pilot Duty plus Motor valves
with:
3850 VA inrush, 700 VA open, 250 VA
hold.

Honeywell EC7890B1010 Relay Module 7800 SERIES EC7890A,B; RM7890A,B,C Relay Module
Electrical Ratings, see Table 1:
Voltage and Frequency:
RM7890A,B,C: 120 Vac (+10/-15%), 50 or 60 Hz (±10%).
EC7890A,B: 220 to 240 Vac (+10/-15%), 50 or 60 Hz (±10%).
Power Dissipation: RM7890: 10W maximum.
Maximum Total Connected Load: 2000 VA.
Fusing: Total Connected Load: 15A maximum, type SC or equivalent, fast blow.
Environmental Ratings:
Ambient Temperature:
Operating: -40°F to +140°F (-40°C to +60°C).
Storage: -40°F to +150°F (-40°C to +66°C).
Humidity: 85% RH continuous, noncondensing.
Vibration: 0.5G environment.
Dimensions: Refer to Fig. 2.
Weight:
EC7890/RM7890 with Dust Cover: 1 pound 13 ounces (822 grams), unpacked.
IMPORTANT
Flame Detection System available for use with EC7890/RM7890. To select your Plug-in Flame Signal Amplifier and applicable Flame Detector, see Table 5.

DimensionsHoneywell EC7890B1010 Relay Module 7800 SERIES EC7890A,B; RM7890A,B,C Relay Module
Accessories:
Keyboard Display Modules (KDM):
S7800A1001 English language.
S7800A1035 French language.
S7800A1043 German language.
S7800A1050 Italian language.
S7800A1068 Spanish language.
S7800A1118 Katakana (Japanese) language.
S7800A1126 Portuguese language.
Communications:
Q7700A1014 Network Interface Unit, 120 Vac, 50/60 Hz applications, external modem required.
Q7700B1004 Network Interface Unit with universal 100 to 250 Vac, 50/60 Hz external power supply, external modem required.
QS7800A1001 ControlBus Module, standard.
QS7800B1000 ControlBus Module, multidrop.
QS7850A1006 ControlBus Module, General Purpose Interface.
ZM7850A1001 Combustion System Managerô software.
S7810A1009 Data ControlBus Module (if no KDM is used).
S7810B1007 Data ControlBus Module, Multi-Drop Switch Module.
S7810M1003 ModBus Module.
S7810M1029 ModBus Module for EC7890A1029, EC7890B1028.
Miscellaneous:
A7800A1002 7800 SERIES Tester.
S7820A1007 Remote Reset Module.
S7830A1005 Expanded Annunciator, 120 Vac, 50/60 Hz.
221729 Dust Cover, Relay Module.
123514A Rectification Flame Simulator.
203659 Ultraviolet Flame Simulator.
 
Table 5. Flame Detection Systems.
Plug-in Flame Signal Amplifiers Applicable Flame Detectors
Type Color Self-Checking Model     Flame
   Failure
Response
Time (sec)a
Fuel Type Models
Rectification Green Dymanic Self-Check R7824Cb,c,hi Gas, oil,
coal
Ultraviolet (Purple
Peeper)
C7024E,F
No R7847Ag 0.8/1 or 2/3 Gas Rectifying Flame Rod
Holdersj
C7004, C7007, C7011
Complete Assemblies:
C7008, C7009, Q179
No R7847Ag 2/3 Gas, oil,
coal
Ultraviolet (Purple
Peeper)
C7012A,C.
Dynamic Ampli-
Check
R7847Bd,g 0.8/1 or
2/3
Gas Rectifying Flame Rod
Holdersb
C7004, C7007, C7011
Complete Assemblies:
C7008, C7009, Q179
Dynamic Ampli-
Check
R7847Bd,g 2/3 Gas, oil,
coal
Ultraviolet (Purple
Peeper)
C7012A,C
Dynamic Self-Check R7847Cc,e,h 2/3 Gas, oil,
coal
Ultraviolet (Purple
Peeper)
C7012E,F
Infrared Red No R7848A 2/3 Gas, oil,
coal
Infrared (Lead
Sulfide)
C7015
Dynamic Ampli-
Check
R7848Bd Gas, oil,
coal
Infrared (Lead
Sulfide)
C7015
Ultraviolet Purple No R7849A 0.8/1 or
2/3
Gas, oil Ultraviolet
(Minipeeper)
C7027, C7035, C7044f
Dynamic Ampli-
Check
R7849Bd 0.8/1 or
2/3
Gas, oil Ultraviolet
(Minipeeper)
C7027, C7035, C7044f
Dynamic Self-Check R7861Ac,e 0.8/1 or
2/3
Gas, oil,
coal
Ultraviolet C7061
Blue Dynamic Self-Check R7886Ac,e 2/3 Gas, oil,
coal
Ultraviolet (Adjustable
Sensitivity)
C7076
Optical White Dymanic Ampli-
Check
R7851B 0.8/1 or 2/3 Gas, oil,
coal
Optical (UV, IR,
Visible Light)
C7927, C7935, C7915,
C7962
Dynamic Self-Check R7851Cc 2/3 Gas, oil,
coal
Optical (UV only) C7961
a Flame Failure Response Time (FFRT) depends on selection of amplifier and 7800 SERIES Relay Module.
b R7824C is used only with the 24 Vdc RM7824 Relay Module and C7024E,F Flame Detectors.
c Circuitry tests all electronic components in flame detection system (amplifier and detector) 12 times a minute during burner operation and shuts down burner if detection system fails.
d Circuitry tests flame signal amplifier 12 times a minute during burner operation and shuts down burner if amplifier fails.
e 200/220/240 Vac applications require a 120 Vac, 10 VA minimum stepdown transformer (not provided) to drive the shutter. Applies to R7847C series 3 or greater; R7886A series 2 or greater; R7861 series 1 or greater. Fig. 2 shows flame detector wiring.
f Use C7027, C7035 and C7044 Flame Detectors only on burners that cycle on-off at least once every twenty-four hours. Use C7012E,F Flame Detector with R7847C Amplifier, C7061A Ultraviolet Detector with R7861A Amplifier or C7076A Flame Detector with R7886A Amplifier as ultraviolet flame detection system for appliances with burners that remain on continuously for twenty-four hours or longer.
g R7847A,B Amplifiers with 0.8/1 second FFRT should not be used with C7012A,C Solid State Ultraviolet Detectors.
h R7824C Series 2 and greater and R7847C Series 4 and greater check flame detector system when flame reaches 1.5 Vdc or at 4.5 seconds, whichever occurs first.
i Order flame rod separately; see flame detector Instructions for holder.
 
Honeywell EC7890B1010 Relay Module 7800 SERIES EC7890A,B; RM7890A,B,C Relay Module
Honeywell EC7890B1010 Relay Module 7800 SERIES EC7890A,B; RM7890A,B,C Relay Module
Honeywell EC7890B1010 Relay Module 7800 SERIES EC7890A,B; RM7890A,B,C Relay Module

Honeywell EC7890B1010 Relay Module 7800 SERIES EC7890A,B; RM7890A,B,C Relay Module
Honeywell EC7890B1010 Relay Module 7800 SERIES EC7890A,B; RM7890A,B,C Relay Module
Honeywell EC7890B1010 Relay Module 7800 SERIES EC7890A,B; RM7890A,B,C Relay Module
Honeywell EC7890B1010 Relay Module 7800 SERIES EC7890A,B; RM7890A,B,C Relay Module
Honeywell EC7890B1010 Relay Module 7800 SERIES EC7890A,B; RM7890A,B,C Relay Module
Honeywell EC7890B1010 Relay Module 7800 SERIES EC7890A,B; RM7890A,B,C Relay Module

https://bnsens.en.made-in-china.com/product/NfTUhjyAXbVp/China-Honeywell-Midas-Gas-Detector-MIDAS-K-O3X.html
 

BNSENS (Nanjing) Sensor Technology Co., Ltd. is located in Nanjing, China. It is a high-tech enterprise specializing in the development, manufacturing and trade of sensor products. The company has brought together a group of outstanding technical experts in various fields such as automation, electronics, machinery and computers. All employees of the company have college degrees or above. It adopts the world-class management and operation model and 6 sigma quality system. At present, the company's main products are pressure, liquid level, flow, current, switches, etc. The company's users are all over the country, and some products have been exported to Japan, South Korea and Southeast Asia.

Since its inception, the company has been based on the technical accumulation and management standards of American sensor giants. It is composed of senior engineers and managers who have served in multinational companies for many years, and has rapidly developed various pressure sensors, transmitters, liquid level, flow meters, pressure switches, digital meters, current sensors, proximity switches and other products. After years of unremitting efforts, it has become one of the leading suppliers in the domestic automation industry. Our pressure transmitters can achieve an accuracy of more than 3/10, 000. The products have been widely used in oil, natural gas, electricity, chemical industry, metallurgy, building materials, food, light industry, environmental protection, aerospace, tap water, municipal and other industries.

It is a sensor science and technology innovation company that masters the core technology of MEMS chips. The company has a research and development center in Minnesota, USA. The leader is Dr. Pan Hanjin, a famous scientist in the sensor industry. Dr. Pan Hanjin has been deeply involved in the sensor industry for more than 20 years and is an expert in the sensor industry.

The company has a number of ASIC chips independently developed, which are widely used in industrial, automotive, home appliance and other markets.

BNSENS (Nanjing) Sensing Technology Co., Ltd. is a strategic partner of Honeywell in China. The two parties proposed a plan of East serving East and jointly developed several sensors specifically for the Chinese market. These sensors will be widely used in intelligent manufacturing, Internet of Things, artificial intelligence, and smart home fields. These sensors include: Magnetic sensors, temperature sensors, humidity sensors, force sensors, fire water pressure sensors, equipment vibration sensors, human body status monitoring sensors, motion sensors, etc.

History of BNSENS Company:

BNSENS is a company focusing on sensors, instruments, and electronic components. We are a young company, founded in 1999, just 25 years old, and we are still growing.

1999: The company's first pressure sensor was launched, mainly for the petroleum and petrochemical industries.

2002: The company expanded its product line and launched temperature sensors

2005: Started producing high-precision pressure sensors for the test and measurement market

2006: Became an official authorized agent of Honeywell

2009: Introduced the Six Sigma management system, and the product qualification rate was greatly improved

2010: Became a supplier of Emerson

2011: We started selling SICK sensors

2014: Introduced the sensor production line from Germany, developed more industrial control sensors, and cooperated with TSMC

2015: Cooperated with Siemens in Vietnam

2017: The factory moved to Nanjing High-tech Zone

2019: Became a national high-tech enterprise in China

2023: We started selling products from Infineon and Rohm

BNSENS, The Future Starts Here.
  
Honeywell EC7890B1010 Relay Module 7800 SERIES EC7890A,B; RM7890A,B,C Relay Module
Honeywell EC7890B1010 Relay Module 7800 SERIES EC7890A,B; RM7890A,B,C Relay Module
Honeywell EC7890B1010 Relay Module 7800 SERIES EC7890A,B; RM7890A,B,C Relay Module
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier