Customization: | Available |
---|---|
Function: | Automatic Control, Protection, Monitoring, Measurement |
Certification: | RoHS, CCC, ISO: 9001, CE |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
GENERAL SPECIFICATION | |||
Capacity | Up to 8 channels with base unit, up to 16 channels with expansion unit | ||
Type of inputs | 2 or 3 wires,mA, mV, max. 15W per channel, max 40W total (with dedicated A/V drive) / 68W total (without dedicated A/V drive) | ||
Size (wall-mounted version) | 426 mm × 300 mm × 156 mm (16.8"x 11.8"x 6.1") | ||
Housing Material | Polycarbonate ABS | ||
Weight | Max 8.5 kg (18.7 lb), max 17 kg (37.4 lb) with expansion unit | ||
USER INTERFACE (UI) - CONTROLLER ONLY | |||
Display | 7''colour LCD touchscreen. Graphic User Interface | ||
Visual indicators | 3 LEDs for master indicators. LED for each channel. Green: Normal; Yellow: Fault: Inhibit; Red: Alarm | ||
Audible alarm | ≥ 70dB @ 1m | ||
Button | Common for reset/mute operation | ||
Language | English, French,German, Italian, Dutch, Spanish, Portuguese, Russian, Chinese | ||
POWER SUPPLY* | |||
Power AC | 110/220VAC, 50-60Hz Manual switching | ||
Power DC | 18 to 32 VDC (+/-10%) Typical 24VDC | ||
Power consumption | Max 105W (including detector and external devices), max 210W with expansion unit | ||
ENVIRONMENTAL | |||
Operating | -10°C to +55°C (14°F to +131°F) continuous, up to 95% RH (non-condensing), IP65 and NEMA 4X | ||
Storage | Instrument -25°C to +60°C. (-13°F to +140°F), up to 95% RH (non-condensing) | ||
4~20mA input | 2 or 3 wire, 2/4/8 channel modules, 10/12/16 with expansion unit | ||
mV input | Catalytic type flammable gas detectors (Honeywell models). 2/4/8 channel modules, 10/12/16 with expansion unit | ||
Dual Input | 2 channel mA + 2 channel mV module or 4 channel mA + 4 channel mV module | ||
Relay output | 12 or 24 relay outputs, NO/C/NC changeover, 1.7A@30VDC/250VAC, user configurable - energised/de-energised, latching/non latching, time delay |
||
4~20mA output | 4 or 8 isolated repeated mA outputs, 0-22mA, 0-100%FSD = 4-20mA | ||
Common inputs | Remote reset, remote inhibit | ||
Common outputs | Four powered A/V outputs for alarms and fault, three common alarm outputs | ||
APPROVALS | |||
Electromagnetic Compatibility and Electrical Safety |
EMC/RFI (EN 50270:2015) LVD (EN 61010-1:2010) CSA-C22.2 No. 61010-1-04 UL 61010-1 (3rd Edition) and 508 |
||
Performance | EN 50271:2010; EN 60079-29-1:2016; EN 45544-1 /-2 /-3:2015; EN 50104:2010 C22.2 No. 152-M1984, ISA 12.13.01 |
||
Safety Integrity | IEC 61508:2010 Ed.2 SIL2, EN 50271:2010 | ||
Hazardous Location | Class I, Division 2, Group A, B, Cand D or non-hazardous only | ||
Marine | MED (Item No.: 3.54) | ||
OTHERS | |||
Backup battery | 22.2V Lithium Ion Battery, 2600mAh capacity (>30 minutes for typical system) | ||
Data logging | Configuration, logged events and data | ||
Communication | MODBUS TCP, WEB monitoring and MODBUS RTU |