Honeywell C7061A1020/U, C7061A1046/U, C7061A1053/U C7061A Dynamic Self-Check Ultraviolet Flame Detector

Product Details
Customization: Available
Manufacturer: Honeywell
Current: 3.5 mA to 7.5
Still deciding? Get samples of $ !
Request Sample
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Fast Delivery
The supplier can deliver the goods within 30 days
Quality Assurance
The supplier provides quality assurance
100% Finished Products Inspection
The supplier inspects 100% of finished products.
to see all verified strength labels (19)
  • Honeywell C7061A1020/U, C7061A1046/U, C7061A1053/U C7061A Dynamic Self-Check Ultraviolet Flame Detector
  • Honeywell C7061A1020/U, C7061A1046/U, C7061A1053/U C7061A Dynamic Self-Check Ultraviolet Flame Detector
  • Honeywell C7061A1020/U, C7061A1046/U, C7061A1053/U C7061A Dynamic Self-Check Ultraviolet Flame Detector
  • Honeywell C7061A1020/U, C7061A1046/U, C7061A1053/U C7061A Dynamic Self-Check Ultraviolet Flame Detector
  • Honeywell C7061A1020/U, C7061A1046/U, C7061A1053/U C7061A Dynamic Self-Check Ultraviolet Flame Detector
  • Honeywell C7061A1020/U, C7061A1046/U, C7061A1053/U C7061A Dynamic Self-Check Ultraviolet Flame Detector
Find Similar Products

Basic Info.

Model NO.
C7061A1020/U
Maximum Pressure Rating
5 psi (34.5 kPa)
Operating Temperature
-18 °C to +121 °C
Voltage
2.2Vdc to 4.98 Vdc
Condition
Original New
Transport Package
Carton
Trademark
Honeywell

Product Description

Product Description

The C7061A,F are dynamic self-checking flame detectors for sensing the ultraviolet radiation generated by the combustion of gas, oil, or other fuels.

Order guide:
Part Number Description Type
C7061A1020/U UV DETECTOR 120/230V SHUTTER UV Flame Detector
C7061A1046/U UV DETECTOR 120V SHUTTER BH CONN UV Flame Detector
C7061A1053/U UV DETECTOR 120V SHUTTER UV Flame Detector


FEATURES
• Oscillating shutter interrupts ultraviolet radiation reaching the UV sensor 12 times per minute to provide the UV sensor tube checking function. Amplifier circuitry components are checked from the microprocessor in the 7800 Series Control.
• Detectors can be mounted horizontally, vertically or at any other angle. The self-checking C7061 models require faceplate alignment and have integral locating reference points to assure proper shutter mechanism operation.
• Ultraviolet radiation sensing tube and quartz viewing window are field replaceable.
• Threaded conduit fitting and color-coded leadwires allow rapid electrical installation.
• Models available using Brad Harrison® 41310 connector.
• Two flame detectors can be wired in parallel to reduce nuisance shutdowns in difficult flame sighting applications.
• -40°F (-40°C) rated ultraviolet sensing tube.
• Incorporates UV sensor tube checking feature; used with R7861 Dynamic Self-check Amplifiers.
• Housing meets NEMA 4 enclosure standards (C7061A).
• Protective heat block built into mounting flange. C7061F
• Housing designed to be explosion-proof and Underwriters Laboratories Inc. listed for use in hazardous locations; Class I, groups C and D; and Class II, groups E, F and G.
• Viewing window rated for 100psi (690 kPa). C7061F C7061A

SPECIFICATIONS
IMPORTANT
The specifications in this publication do not include normal manufacturing tolerances. Therefore, this unit may not exactly match the specifications listed. This product is tested and calibrated under closely controlled conditions, and minor differences in performance can be expected if those conditions are changed.

Models:
C7061A Dynamic Self-Check Ultraviolet Flame Detector.
C7061F Dynamic Self-Check Ultraviolet Flame Detector. (Same as C7061A except with explosion-proof housing for use in hazardous locations).

Electrical Ratings:
Voltage and Frequency:
The C7061 is powered from the Flame Safeguard unit that delivers the necessary voltages to operate the tube and shutter.

Ambient Operating Temperature Ratings
(Outside the Case): -40°F to 175°F (-40°C to 80°C) using part no. 129464N UV Sensing Tube.
Storage Temperature Ratings: -60°F to 175°F (-50°C to 80°C).

Housing:
C7061A:
Violet, cast-aluminum cover. Separate mounting flange (with heat block) and faceplate provide heat insulation and sealoff. Meets NEMA 4 enclosure requirements (indoor, outdoor protection; rain-tight, dust-tight, hose-directed water protection). Optional water jacket available; see Accessories. C7061F: Explosion-proof, two-piece, violet, cast aluminum.

Pressure Rating of Quartz Viewing Window: C7061A: 20 psi (138 kPa), see Replacement Parts. C7061F: 100 psi (690 kPa).

Pressure Rating of Quartz Focusing Lens: 20 psi (138 kPa), see Accessories

 
Mounting:
C7061A: Mounting flange with 3/4 NPT internal threads for attaching to sight pipe.
C7061A1046: Mounting flange with 1 inch NPT internal threads for attaching to sight pipe.
C7061F: Pipe union with 1 inch NPT internal threads for attaching to sight pipe.

Wiring Connections: Leadwire: NEC Class 1 color coded. Length: 8 ft (2.4m).

Threaded Leadwire Faceplate Opening: 1/2-14 NPSM internal threads for attaching conduit.

Connector: C7061A1038 and C7061A1046: Brad Harrison® 41310.

Weight:
C7061A: 2.6 lbs (1.2 kg).
C7061F: 14.5 lbs (6.6 kg).

Serviceability:
C7061A: Field replaceable ultraviolet sensing tube viewing window, coil and shutter assembly gaskets.
C7061F: Field replaceable self-checking coil and shutter assembly.

SIL 3 Capable:
The C7061A or F when used with a R7861 self-check amplifier in Relay Module EC7810A, 20A, 30A, 40L, 50A; RM7800[E,G,L,M], 30A, 38[A,B,C], 40[E,G,L,M] 50A, 90[A,B,C,D], 97[A,C], 98A is SIL 3 Capable in a properly designed Safety Instrumented System. See form number 65-0312 for Certificate Agreement.

Approvals:
Underwriters Laboratories Inc. Listed: File Number MP268, Guide Number MCCZZ. Canadian Standards Association Certified: Master File LR95329-1. Factory Mutual Approved: 14740.01. SwissRe (formerly Industrial Risk Insurers) Acceptable. C7061F: For use in hazardous locations; Class I, Groups C and D; Class II, Groups E, F, and G; File no. E34649.

Replacement Parts: All Models: 129464N Ultraviolet Sensing Tube; -40°F (-40°C).
 
Honeywell C7061A1020/U, C7061A1046/U, C7061A1053/U C7061A Dynamic Self-Check Ultraviolet Flame Detector
Honeywell C7061A1020/U, C7061A1046/U, C7061A1053/U C7061A Dynamic Self-Check Ultraviolet Flame Detector
Install the Sight Pipe (Fig. 5)
After you have determined the location and sighting angle, select the sight pipe. A black iron pipe with a diameter of at least 1-1/2 in. (38 mm) is recommended. Do not use stainless steel or galvanized pipe because they reflect ultraviolet radiation internally and complicate aiming the pipe. Sight pipes with diameters 2 to 3 in. (51 to 76 mm) produce better results for horizontal rotary burners, which require wide viewing angles. A wide viewing angle can also be obtained by using a short sight pipe.
 
Table 1. Flame Signal.
Flame Detector
Plug-in Flame
Signal Amplifier
Flame Safeguard Control(s) Minimuma
Acceptable Steady
Voltage (Vdc)

Maximum Expected
      Voltage (Vdc)
C7061A,F R7861 Dynamic
Self-Checka,b
RM7800E,G,L,M; RM7823A;
RM7838A,B,C; EC7823A;
RM7840E,G,L,M; RM7890B;
EC7890B; RM7895A,B,C,D;
RM7896A,B,C,D; EC7895A,C;
EC/RM7885; EC7810; EC7820;
EC/RM7830; EC7850.
1.25  5.0 
a Shutter operation of the C7061A causes fluctuations in the voltage reading. Read the average stable voltage, disregarding the peaks.
b Shutter operates at 12 cycles per minute.
  
 
Honeywell C7061A1020/U, C7061A1046/U, C7061A1053/U C7061A Dynamic Self-Check Ultraviolet Flame Detector
Honeywell C7061A1020/U, C7061A1046/U, C7061A1053/U C7061A Dynamic Self-Check Ultraviolet Flame Detector
Honeywell C7061A1020/U, C7061A1046/U, C7061A1053/U C7061A Dynamic Self-Check Ultraviolet Flame Detector
 
Honeywell C7061A1020/U, C7061A1046/U, C7061A1053/U C7061A Dynamic Self-Check Ultraviolet Flame Detector
Honeywell C7061A1020/U, C7061A1046/U, C7061A1053/U C7061A Dynamic Self-Check Ultraviolet Flame Detector
Honeywell C7061A1020/U, C7061A1046/U, C7061A1053/U C7061A Dynamic Self-Check Ultraviolet Flame Detector
 
Honeywell C7061A1020/U, C7061A1046/U, C7061A1053/U C7061A Dynamic Self-Check Ultraviolet Flame Detector
Honeywell C7061A1020/U, C7061A1046/U, C7061A1053/U C7061A Dynamic Self-Check Ultraviolet Flame Detector
Honeywell C7061A1020/U, C7061A1046/U, C7061A1053/U C7061A Dynamic Self-Check Ultraviolet Flame Detector

https://bnsens.en.made-in-china.com/product-group/bopTdXVcfIWz/Gas-Sensor-and-Flame-Detector-catalog-1.html?pv_id=1ii1a7sfk23c&faw_id=1ii1a7th59a
 
Honeywell C7061A1020/U, C7061A1046/U, C7061A1053/U C7061A Dynamic Self-Check Ultraviolet Flame Detector
Honeywell C7061A1020/U, C7061A1046/U, C7061A1053/U C7061A Dynamic Self-Check Ultraviolet Flame Detector
Honeywell C7061A1020/U, C7061A1046/U, C7061A1053/U C7061A Dynamic Self-Check Ultraviolet Flame Detector

BNSENS (Nanjing) Sensor Technology Co., Ltd. is located in Nanjing, China. It is a high-tech enterprise specializing in the development, manufacturing and trade of sensor products. The company has brought together a group of outstanding technical experts in various fields such as automation, electronics, machinery and computers. All employees of the company have college degrees or above. It adopts the world-class management and operation model and 6 sigma quality system. At present, the company's main products are pressure, liquid level, flow, current, switches, etc. The company's users are all over the country, and some products have been exported to Japan, South Korea and Southeast Asia.

Since its inception, the company has been based on the technical accumulation and management standards of American sensor giants. It is composed of senior engineers and managers who have served in multinational companies for many years, and has rapidly developed various pressure sensors, transmitters, liquid level, flow meters, pressure switches, digital meters, current sensors, proximity switches and other products. After years of unremitting efforts, it has become one of the leading suppliers in the domestic automation industry. Our pressure transmitters can achieve an accuracy of more than 3/10, 000. The products have been widely used in oil, natural gas, electricity, chemical industry, metallurgy, building materials, food, light industry, environmental protection, aerospace, tap water, municipal and other industries.

It is a sensor science and technology innovation company that masters the core technology of MEMS chips. The company has a research and development center in Minnesota, USA. The leader is Dr. Pan Hanjin, a famous scientist in the sensor industry. Dr. Pan Hanjin has been deeply involved in the sensor industry for more than 20 years and is an expert in the sensor industry.

The company has a number of ASIC chips independently developed, which are widely used in industrial, automotive, home appliance and other markets.

BNSENS (Nanjing) Sensing Technology Co., Ltd. is a strategic partner of Honeywell in China. The two parties proposed a plan of East serving East and jointly developed several sensors specifically for the Chinese market. These sensors will be widely used in intelligent manufacturing, Internet of Things, artificial intelligence, and smart home fields. These sensors include: Magnetic sensors, temperature sensors, humidity sensors, force sensors, fire water pressure sensors, equipment vibration sensors, human body status monitoring sensors, motion sensors, etc.

History of BNSENS Company:

BNSENS is a company focusing on sensors, instruments, and electronic components. We are a young company, founded in 1999, just 25 years old, and we are still growing.

1999: The company's first pressure sensor was launched, mainly for the petroleum and petrochemical industries.

2002: The company expanded its product line and launched temperature sensors

2005: Started producing high-precision pressure sensors for the test and measurement market

2006: Became an official authorized agent of Honeywell

2009: Introduced the Six Sigma management system, and the product qualification rate was greatly improved

2010: Became a supplier of Emerson

2011: We started selling SICK sensors

2014: Introduced the sensor production line from Germany, developed more industrial control sensors, and cooperated with TSMC

2015: Cooperated with Siemens in Vietnam

2017: The factory moved to Nanjing High-tech Zone

2019: Became a national high-tech enterprise in China

2023: We started selling products from Infineon and Rohm

BNSENS, The Future Starts Here.

  
Honeywell C7061A1020/U, C7061A1046/U, C7061A1053/U C7061A Dynamic Self-Check Ultraviolet Flame Detector
Honeywell C7061A1020/U, C7061A1046/U, C7061A1053/U C7061A Dynamic Self-Check Ultraviolet Flame Detector
Honeywell C7061A1020/U, C7061A1046/U, C7061A1053/U C7061A Dynamic Self-Check Ultraviolet Flame Detector
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier