Characteristic
|
Min.
|
Typ.
|
Max.
|
Unit
|
|
Supply voltage (Vsupply):1, 2, 3
pressure ranges >60 mbar | 6 kPa | 1 psi: |
||||
|
3.3 Vdc
|
3.0 | 3.3 | 3.6 | Vdc |
|
5.0 Vdc
|
4.75 | 5.0 | 5.05 | |
|
Pressure ranges <40 mbar | 4 kPa | 20 inH2O:
|
||||
|
3.3 Vdc
|
3.27 | 3.3 | 3.33 | Vdc |
|
5.0 Vdc
|
4.95 | 5.0 | 5.05 | |
|
Supply current:
|
||||
|
3.3 Vdc
|
- | 2.1 | 2.8 | mA |
|
5.0 Vdc
|
- | 2.7 | 3.5 | |
|
Operating temperature range4
|
-40 [-40]
|
- | 85 [185] |
°C [°F]
|
|
Compensated temperature range5
|
-20 [-4]
|
- |
85 [185]
|
°C [°F]
|
|
Startup time (power up to data ready)
|
- | - | 5 | ms |
|
Response time
|
- | 1 | - | ms |
|
Clipping limit:
|
||||
|
upper
|
- | - | 97.5 |
%Vsupply
|
|
lower
|
2.5 | - | - | |
|
Accuracy6
|
- | - |
±0.25
|
%FSS BFSL8
|
|
Output resolution
|
0.03 | - | - |
%FSS
|
|
Orientation sensitivity (±1 g):7, 9
|
||||
|
pressure ranges <40 mbar | 4 kPa | 20 inH2O
|
- |
±0.1
|
- |
%FSS8
|
|
pressure ranges <2.5 mbar | 250 Pa | 1 inH2O
|
- |
±0.2
|
- | |