Customization: | Available |
---|---|
Power Supply Voltage: | 12~32VDC |
Output Type: | 4~20mA+Hart |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Sensory type | Basic accuracy 1 | Rated range | Standard | Minimum range2 | The temperature effect of every 1.0ºC 3 change in ambient temperature |
||
Fixed value | % of the range | ºC | ºC | Fixed value | % of the range | ||
Pt100 | 0.15ºC | ±0.1 | -200~+850 | IEC60751 | 25ºC | 0.01ºC | ±0.01 |
Ni100 | 0.3ºC | ±0.1 | -60~+250 | DIN73460 | 25ºC | 0.01ºC | ±0.01 |
Ω | 0.2Ω | ±0.1 | 0~+1000 | 30Ω | 20mΩ | ±0.01 |
Ambient temperature (rated) | -40~85ºC |
Humidness | 0~95%RH |
Vibration | Max. 4g(25~100Hz) |
Power source | 8~30V DC |
Supply voltage effect | ≤0.005% range /V DC |
Preheating time | Five minutes |
Response time (configurable) | 0.33~60s |
Signal output range | 4~20mA |
Refresh time | 135ms |
Loop resistance | ≤(power supply voltage -8)/0.023A 0~870Ω |
Configurable | 3.5~4mA Downscale,20~23mA Upscale |
NAMUR NE43 Upscale | 23mA |
NAMUR NE43 Downscale | 3.5mA |
KEMA 06 ATEX 0042 X | II I GD,T80ºC ⋯T105ºC EEX ia II C T4⋯T6 |
T4 Maximum ambient temperature | 85ºC |
T6 Maximum Ambient temperature | 60ºC |
Application area | 0,1,2,20,21 and 22 |
Ui(max) | 30VDC |
Ii(max) | 120mADC |
Pi(max) | 0.84W |
Li(max) | 10μH |
Ci(max) | 1.0nF |
Uo(max) | 27VDC |
Io(max) | 7mADC |
Po(max) | 45mW |
Lo(max) | 34mH |
Co(max) | 90nF |