Bafs4000b Mass Gas Flow Sensor with 1-5 V Analog Output

Product Details
Customization: Available
Structure Type: Measuring Core
Measuring Medium: Gas
Manufacturer/Factory & Trading Company
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (19)
  • Bafs4000b Mass Gas Flow Sensor with 1-5 V Analog Output
  • Bafs4000b Mass Gas Flow Sensor with 1-5 V Analog Output
  • Bafs4000b Mass Gas Flow Sensor with 1-5 V Analog Output
  • Bafs4000b Mass Gas Flow Sensor with 1-5 V Analog Output
  • Bafs4000b Mass Gas Flow Sensor with 1-5 V Analog Output
  • Bafs4000b Mass Gas Flow Sensor with 1-5 V Analog Output
Find Similar Products
  • Overview
  • Product Parameters
  • Dimensions
  • Disclaimer
Overview

Basic Info.

Model NO.
BAFS4000B
Certification
CE
Customized
Customized
Test Conditions
Vin=12±0.01VDC,Ta=25°c
Relative Humidity
40%<Relative Humidity<60%
Temperature Range
-25ºC ~+85ºC
Storage Temperature
-40ºC ~ 90ºC
Humidity
0~100%Rh
Impact Resistant
100g
Supply Voltage (5)
8~18VDC

Product Description

BAFS4000B mass gas flow sensor is made of micro-electro-mechanical system (MEMS) flow sensor chip, which is suitable for clean and relatively dry gas measurement of various uses, realizing the digitalization, intelligence and high security of the equipment, and has the role and improvement of traditional industry innovation. Wide range of flow measurement range to meet the flow measurement needs of different equipment in the industry, high sensitivity, high reliability, high stability and low cost performance characteristics can promote the industry to energy saving and intelligent direction development.

BAFS4000 series products are based on MEMS traffic sensing unit, high precision digital processing and calibration circuit (MCU) composition, integrated high-resolution Delta-σ A/D converter and have internal calibration function Qun circuit and MCU processor together to ensure that the sensor signal real-time effective acquisition, obtain accurate traffic signal, And the corresponding compensation algorithm is processed internally, so there is no need to do any external calibration compensation, can ensure high precision flow output; Friendly digital output communication line, users can get corresponding data and information very easily; Product application range is very broad.


Charcteristics:

  • The traffic ranges from 0SLPM to 300SLPM
  • High accuracy (1.5% F.S accuracy)
  • Linear output and temperature compensation
  • Maintain long term stability with minimum zero drift
  • Forward and reverse gas flow measurement
  • Solid sensing core (no surface cavities or fragile film), resistant to clogging and pressure impact
  • Analog output (1-5 V) (digital I2C communication output is available)
  • Fast response time (20ms response time)
  • The sensor is resistant to condensation


Application
• ventilator /respirator
• Oxygen generator
• Gas mask and respirator
• Spray
• Continuous positive airway pressure (CPAP) devices
• Anesthesia delivery
• Leak detection
• The spectrometer
• Mass flow controller
• Environmental climate control
• Fuel cell control

Product Parameters
Test conditions VIN=12±0.01VDC,Ta=25°C
Relative humidity 40%<relative humidity<60%
Temperature range -25ºC ~+85ºC
Storage temperature -40ºC ~ 90ºC
Humidity 0~100%RH
Impact resistant 100g
Analog voltage output (3) 1~5VDC
Supply voltage (5) 8~18VDC
Zero voltage 0.95...1~1.05VDC
Zero drift 0.2%F.S
Resolution (4) 0.1%F.S
Load 100KΩ
Precision 1.5%F.S
Response time 20ms  
Supply current 20~30mA
Whole material Silicon carbide, epoxy resin, polyphenylene sulfide, FR4, silicon as seal
  Flow range  Unit  Maximum flow rate (m/s)
BAFS4003BV -12 ~12 SLM 0.527
BAFS4004BV -20 ~20 SLM 0.877
BAFS4005BV -35 ~35 SLM 1.535
BAFS4100BV -50 ~50 SLM 2.193
BAFS4101BV -100 ~100 SLM 4.387
BAFS4102BV -150 ~150 SLM 6.58
BAFS4103BV -200 ~200 SLM 8.773
BAFS4104BV -300 ~300 SLM 13.16

NOTE:

1. The range between 10SLM and 300SLM can be customized

2. SLM: standard litres per minute. Standard conditions: 0ºC and 1 atmosphere

3. 0~3V output is also available

4. including temperature drift and linear error

5. 5V power supply voltage can be selected


Bafs4000b Mass Gas Flow Sensor with 1-5 V Analog Output
Bafs4000b Mass Gas Flow Sensor with 1-5 V Analog Output
 

Dimensions

Bafs4000b Mass Gas Flow Sensor with 1-5 V Analog Output


 

Disclaimer

Bafs4000b Mass Gas Flow Sensor with 1-5 V Analog Output

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier