Honeywell STD725-E1AC4AS-1-G-AHS-11S-A-00A0-00-0000 Differential Pressure Transmitters -100kpa~100kpa

Product Details
Customization: Available
Type: Differential Pressure Transmitter
Structure Type: Diffused Silicon Pressure Transmitter
Still deciding? Get samples of US$ 555/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Fast Delivery
The supplier can deliver the goods within 30 days
Quality Assurance
The supplier provides quality assurance
100% Finished Products Inspection
The supplier inspects 100% of finished products.
to see all verified strength labels (19)
  • Honeywell STD725-E1AC4AS-1-G-AHS-11S-A-00A0-00-0000 Differential Pressure Transmitters -100kpa~100kpa
  • Honeywell STD725-E1AC4AS-1-G-AHS-11S-A-00A0-00-0000 Differential Pressure Transmitters -100kpa~100kpa
  • Honeywell STD725-E1AC4AS-1-G-AHS-11S-A-00A0-00-0000 Differential Pressure Transmitters -100kpa~100kpa
  • Honeywell STD725-E1AC4AS-1-G-AHS-11S-A-00A0-00-0000 Differential Pressure Transmitters -100kpa~100kpa
  • Honeywell STD725-E1AC4AS-1-G-AHS-11S-A-00A0-00-0000 Differential Pressure Transmitters -100kpa~100kpa
  • Honeywell STD725-E1AC4AS-1-G-AHS-11S-A-00A0-00-0000 Differential Pressure Transmitters -100kpa~100kpa
Find Similar Products
  • Overview
  • Product Parameters
  • Dimension
Overview

Basic Info.

Model NO.
STD725-E1AC4AS-1-G-AHS-11S-A-00A0-00-0000
Pressure range
-100kpa~100kpa
IP Rating
IP67
Certification
CE
Wire Type
Two- Wire
Analog Output
4mA ~ 20 Ma. Hart 7 Protocol
Supply Voltage Effect
0.005% Span Per Volt
Transmitter Turn on Time
2.5s
Place of Origin
Tianjin, China
Material
316L Stainless Steel

Product Description

As a member of the SmartLine® product line, the STD700 is a high-performance differential pressure transmitter that utilizes advanced sensor technology. By combining differential pressure measurements with static pressure and temperature compensation on the sensor chip, the STD700 offers exceptional measurement accuracy and stability across a wide range of static pressures and temperatures. SmartLine® has been thoroughly tested and meets the Experion® PKS standards, ensuring high levels of compatibility and integration capability. SmartLine® products are designed to meet the stringent demands of pressure measurement applications with ease.

 
Innovative Features:
  • Calibration range accuracy up to 0.05%, with 0.04% optional
  • Stability: 0.020% of span, maintained for 10 years
  • Automatic static pressure and temperature compensation
  • Range ratio of 100:1
  • Fast response time of up to 100 ms
  • Easy-to-use and intuitive display functions
  • External zero, span, and configuration functions
  • Comprehensive self-diagnostics
  • Integrated dual-seal design based on ANSI/NFPA 70-202 and ANSI/ISA 12.27.0 standards to ensure maximum safety
  • Exceptional static pressure tolerance: 31.5 MPa
  • Standard configuration fully meets SIL2/3 requirements
  • Modular design
  • Extendable warranty up to an additional 4 years

Note: All data provided by Honeywell laboratories

Description:
The SmartLine® series pressure transmitters are designed based on high-performance sensors. Each sensor effectively integrates multiple sensors, combining process pressure measurement with static pressure (for DP models) and temperature measurement used for temperature compensation, thereby achieving superior overall performance.

 

Display Head Options

Standard LCD Display Head:

  • Modular (can be added or removed on-site)
  • Supports HART protocol
  • Adjustable to 0°, 90°, 180°, and 270° positions
  • Measurement units include: Pa, kPa, MPa, kg/cm², Torr, ATM, i4H2O, mH2O, bar, mbar, inH2O, inHg, FT H2O, mmH2O, mmHg, and psi
  • Large screen display (9.95 mm high x 4.20 mm wide) with 2 lines and 8 characters
  • Square root output and write protection indicator
  • Display module features internal configuration buttons for setting and calibrating the transmitter via internal or external keys


Self-Diagnostics:

SmartLine® transmitters all offer digitally accessible diagnostics, which help provide advanced alarms for potential fault events. This significantly reduces planned downtime and lowers overall operating costs.

Configuration Tools

Integrated Internal or External Configuration Button Options:

Transmitters can be configured for all basic parameters using buttons integrated within the display module or external magnetic keys. The integrated external buttons meet all electrical and environmental requirements. For zero/span setting functions, external buttons can be used regardless of whether an LCD display head is selected.

Handheld Configuration:

SmartLine® transmitters support bidirectional communication and configuration between the operator and the transmitter. This is achieved through Honeywell's field configuration toolkit. Honeywell's field configuration toolkit allows for the on-site configuration of HART transmitters and can be used in intrinsically safe environments. All Honeywell transmitters are designed and tested to comply with the provided communication protocols and can be used with any certified handheld configurator.

Computer Configuration:

HART Field Device Manager (FDM) software and FDM Express can be used to manage the configuration of devices.

System Integration:

  • SmartLine® communication protocols comply with the latest HART standards.
  • All SmartLine® transmitter devices have been tested with Experion®, ensuring high compatibility.

Modular Design:

To help control maintenance and inventory costs, all ST700 transmitters feature a modular design, allowing for easy hardware replacements such as adding an LCD display head, replacing electronic modules, or even changing the transmitter diaphragm, without affecting overall performance or equipment safety certification. Each transmitter diaphragm is uniquely characterized and calibrated to provide exceptional performance across a wide range of static pressures and temperatures. Additionally, with Honeywell's modular interface design, electronic modules can be interchanged without compromising performance specifications.   

  • Diaphragm Replacement
  • Addable or Removable LCD Display Head*
  • Replaceable Surge Protection Module (Terminals)*

*Except in explosion-proof environments, on-site replacements can be performed in any electrical environment (including intrinsically safe areas) without violating safety certification regulations.

Honeywell's innovative modular design reduces inventory requirements and maintenance costs without affecting transmitter performance.

Product Parameters

Performance Under Rated Conditions

Parameters Description
Analog Output
Digital Communication
Two-wire, 4mA ~ 20 mA. HART 7 protocol
Fault Output Mode (Configurable)                                  Honeywell Standard                            NAMUR NE 43 Specification
Normal range:                 3.8 -20.8 mA                                            3.8 -20.5 mA
Fault Mode:               ≤ 3.6 mA and ≥ 21.0 mA                        ≤ 3.6 mA and ≥ 21.0 mA

 
Supply Voltage Effect 0.005% span per volt
Transmitter on time (including power and self-test procedure)
2.5s
response time  (Delay + time constant)
100ms
Damping time constants 
Adjust in 0s to 32s,Increments of 0.1 seconds.Windows default:0.50s
Vibration effect
Less than ± 0.1% above the range limit (no damping)
Compliance with IEC 60770-1, site or pipeline requirements,High vibration level (10- 2000Hz: 0.21mm shift / 3g maximum acceleration
Electromagnetic compatibility
Compliance with the IEC 61326-3-1 requirements
Lightning protection options
Leakage current: max. 10 uA @ 42.4 VDC 93C
Impact rating:8/20 uS       5000 A (> 10 impacts)       10000 A (minimum 1 impact)
10/1000 uS           200 A (> 300, secondary impact)
 
Material specification(See the selection guide for availability / restrictions for various models)
Parameter
Description
Membrane material
316L SS ,Hastelloy®C -2762,Monel®4003 , Ta3
Process interface material
316 SS4 , Carbon steel (galvanized)5, Hastelloy C -2766, Monel 4003
Exhaust / drain valve, and the plug1
316 SS4,Hastelloy C -2762
Sheet gasket
Standard equipped with glass-filled PTFE. Viton®And graphite optional.
Table body bolt
Standard with carbon steel (galvanized). Options include 316 SS, NACE A 286 SS, Monel K 500,
Super dual-phase steel and B 7M.
Optional adapters and bolts
The conversion joint material includes 316 SS, Hastelloy®C-276. The bolt material of the conversion
joint depends on the bolt material of the process interface clamp block. The standard converter
O-ring material is made of glass-filled PTFE, Viton®And graphite optional.
mounting bracket
Plate or straight, angle, carbon steel (galvanized), 304SS, or 316SS.
Filler
DC®200 (silicone oil) or CTFE (fluorine oil)
hull
Pure polyester powder coated low copper (<0.4%) aluminum alloy, complying with NEMA 4X, IP66
/ IP67 and NEMA 7 (explosion-proof). Stainless steel casing is optional.
install
Installation is possible almost anywhere using a standard mounting bracket. The bracket is
designed to be mounted over 2 inch (50 mm) vertical or horizontal piping. See Figure 3.
procedural interface
1 / 4 "-NPT or 1 / 2" -NPT (meet DIN requirements).
lead
Accept the max 16 AWG (1.5 mm diameter).
size
See Figure 3.
net weight
3.8 Kg (with aluminum alloy enclosure)
 
1.The exhaust / drain port adopts Teflon®seal.
2.Hastelloy®And C-276 or UNS N 10276.
3.Special materials consulting factory
4. 316 SS or CF8M, 316 SS equivalent.
5.Carbon steel pellet galvanized, is not recommended for wading services because of hydrogen transfer. For this application, use the 316 stainless steel
clips.
6.Hastelloy®And C-276 or UNS N 10276. Provided as indicated, or provide CW 12MW, Hastelloy®C-276 equivalent casting.
 
Dimension

 

Honeywell STD725-E1AC4AS-1-G-AHS-11S-A-00A0-00-0000 Differential Pressure Transmitters -100kpa~100kpa


Power Supply Voltage and Circuit Resistance Diagram and Calculation
Honeywell STD725-E1AC4AS-1-G-AHS-11S-A-00A0-00-0000 Differential Pressure Transmitters -100kpa~100kpa




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier