Honeywell Elster-Instromet RVG Flange Connection G16 – G400 and RVG-ST Standard Thread Connection G10 – G25 Rotary Gas Meters

Still deciding? Get samples of $ !
Request Sample
Product Details
Customization: Available
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Certification: JIS, DIN, ANS, GB, CE, RoHS, ISO
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Fast Delivery
The supplier can deliver the goods within 30 days
Quality Assurance
The supplier provides quality assurance
100% Finished Products Inspection
The supplier inspects 100% of finished products.
to see all verified strength labels (19)
  • Honeywell Elster-Instromet RVG Flange Connection G16 – G400 and RVG-ST Standard Thread Connection G10 – G25 Rotary Gas Meters
  • Honeywell Elster-Instromet RVG Flange Connection G16 – G400 and RVG-ST Standard Thread Connection G10 – G25 Rotary Gas Meters
  • Honeywell Elster-Instromet RVG Flange Connection G16 – G400 and RVG-ST Standard Thread Connection G10 – G25 Rotary Gas Meters
  • Honeywell Elster-Instromet RVG Flange Connection G16 – G400 and RVG-ST Standard Thread Connection G10 – G25 Rotary Gas Meters
  • Honeywell Elster-Instromet RVG Flange Connection G16 – G400 and RVG-ST Standard Thread Connection G10 – G25 Rotary Gas Meters
  • Honeywell Elster-Instromet RVG Flange Connection G16 – G400 and RVG-ST Standard Thread Connection G10 – G25 Rotary Gas Meters
Find Similar Products

Basic Info.

Manufacturer
Honeywell
Meter sizes
G10 – G400
Condition
Original New
Gas Temperature
-20 to +60 °C
Ambient Temperature
-20 to +70 °C
Operating pressure
Max. 20 bar
Protection Class
IP 67 (suitable for outdoor installation)
Housing
Aluminium or cast iron GGG-40; pistons made of alu
Metrological approval
PTB
Atex Approval
Ex-zone 1
Medium
Natural gas, town gas, inert gases, further gases
Reproducibility
< 0.1%
Transport Package
Carton
Trademark
Honeywell

Product Description

Applications
Media: Natural gas, town gas, inert gases
Industry: Gas supply, stove manufacturers, chemical industry.
Tasks: Measurement, control and automatic regulation.
 
Brief information 
RVG: Flange connection G16 - G400
RVG-ST: Standard thread connection G10 - G25

Operating Principle
Elster-Instromet RVG and RVG-ST rotary gas meters are volumemeasuring devices for gaseous media and operate according to the positive displacement principle.
They register the gas volume under operating conditions. In order to correct the measured volume to standard conditions, electronic volume correctors with various characteristics are available.
The actual measuring cell consists of two 8 shaped impellers, which build together with the housing 4 chambers per revolution, which are periodically fi lled and emptied.
The number of revolutions is proportional to the passed volume. The rotation is transferred to a mechanical index, which indicates this volume.

 
General: Rotary meters are characterized by high measuring range and compact dimensions.
Due to their measuring principle they do not require any straight inlet or outlet pipe section. Rotary meters have to be lubricated with oil. For easy access and control of the appropriate oil level the oil chambers on the front and the backside are connected to allow maintenance to be done from the front side only.
The double direction index allows adapting the meter to any fl ow direction. The RVG is available with the latest technology of the Absolute-ENCODER S1D, which enables the most reliable readout of a mechanical index.
The RVG-ST is the smallest meter line from G10 to G25. It has a threaded connection as standard. Optionally it is also available as fl ange version.
The index of the RVG-ST is located in the gas area, while the RVG uses index variants outside the gas area in atmospheric air driven by a magnetic coupler.
 
Main features
• Meter sizes: G10 - G400
• For fl ow rates 0.6 m³/h to 650 m³/h
• Nominal widths DN 25 - DN 150
• Pressure ratings
  PN 10/16 and ANSI 150
• Cast iron housing (GGG 40) or aluminium housing
• High-temperature resistance up to 4 bar for GGG 40
• Optional: double direction index S1D for universal installation and fl ow direction
 
RVG: Rotary Gas Meters / flange connection
Technical data RVG
Gas temperature -20 to +60 °C
Ambient temperature -20 to +70 °C
Operating pressure Max. 20 bar
Protection class IP67 (suitable for outdoor installation)
Housing Aluminium or cast iron GGG-40; pistons made of aluminium
Metrological approval PTB
ATEX approval Ex-zone 1
Media Natural gas, town gas, inert gases, further gases on request
Max. error
± 1 % for Qt - Qmax
± 2 % for Q min - Qt
Qt = 0.2     Qmax, for measuring range ≤ 1:20
Qt = 0.15   Qmax, for measuring range > 1:30
Qt = 0.1     Qmax, for measuring range = 1:50
Qt = 0.05  Qmax, for measuring range > 1:50
Reproducibility < 0.1%
Applicable standards EN 12480, DIN EN 13463-1 and -5, EN 50020:2002
Index variants S1 (standard), Double direction index S1D,
Absolute-ENCODER S1D (option)
Outputs Retrofitable LF-Pulser IN-Sxx (Reed switch)
Retrofitable LF-Pulser IN-W11 (Wiegand sensor, option)
HF-pulser A1K (option)
Pressure/temperature tapping 2 pressure tappings ¼" NPT, 2 thermowells applicable
 
Measuring ranges: according EEC type approval D 95 7.131.06
Size
Measuring
chamber
[dm³]
Start-up
fl ow rate
[m³/h]
Qmin
[m³/h]
national
1:160
Qmin
[m³/h]
National
1:100
Qmin
[m³/h]
National
1:65
Qmin
[m³/h]
EU-Norm
1:20
Qmax
[m³/h]
2xNF
[imp/m³]
HF *
[imp/m³]
(Option)
G 16 DN 50
0.56 0.03       1.3 25 10
~ 14025
G 25 DN 50
0.56 0.03     0.6 2.0 40 10
~ 14025
G 40 DN 50
0.56 0.03   0.6 1.0 3.0 65 10
~ 14025
G 65 DN 50
0.56 0.03 0.6 1.0 1.6 5 100 10
~ 14025
G 100 DN 80
1.07 0.05 1.0 1.6 2.5 8 160 1
~ 7528
G 160 DN 80
2.01 0.1 1.6 2.5 4.0 13 250 1
~ 3882
G 250 DN 100
2.54 0.3 2.5 4.0 6.0 20 400 1
~ 3178
G 400 DN 100
3.65 0.4 4.0 6.5 10 32 650 1
~ 2191
G 400 DN 150
3.65 0.4 4.0 6.5 10 32 650 1
~ 2191
 
LF pulser E1 and PCM
Elster-Instromet RVG rotary meters are commonly equipped with 2 low-frequency (LF) pulse generators and an additional monitoring reed switch (PCM) for detection of line break or interferences caused by magnetic fi elds. These pulse generators are attachable and can be retrofi tted or changed without opening totalizer.
 
LF pulser IN-W11
As an option, it is possible to fit Elster-Instromet RVGs with the Wiegand sensor module IN-W11 instead of the LF pulser module IN-S1x. The IN-W11 is a low-frequency pulser with a defi nite pulse width > 50 ms, which is highly reliable and ensures there is no mechanical wear and tear.

Honeywell Elster-Instromet RVG Flange Connection G16 – G400 and RVG-ST Standard Thread Connection G10 – G25 Rotary Gas Meters
Dimensions and weights
Aluminium   (Dimensions in mm;weight in kg)
Size DN* DN** A B C H Dk DL E K L F Weight
G 16 50  40  335  115  220  222  125  4×M16 180  240  141  171  12 
G 25 50  40  335  115  220  222  125  4×M16 180  240  141  171  12 
G 40 50  40  335  115  220  222  125  4×M16 180  240  141  171  12 
G 65 50  40  335  115  220  222  125  4×M16 180  240  141  171  12 
G 100 80  - 435  165  272  222  160  8×M16 180  290  141  171  16 
G 160 80  100  469  189  280  278  160  8×M16 220  298  168  241  33 
G 250 100  80  529  219  310  278  180  8×M16 220  328  168  241  39 
G 400 100  - 660  290  370  278  180  8×M16 220  421  168  241  50 
G 400 150  100  660  290  370  308  240  8×M20 285  421  168  260  56 
* Standard ** Special model *** Special dimensions in parentheses (at GGG-40)
Standard: Flange PN 10/16 according to DIN 2633; optional: ANSI 150 according to ASME B16.5

GGG-40      (Dimensions in mm;weight in kg)
Size DN* DN** A B C H Dk DL E K L F*** Weight
G 16 50  40  335  115  220  222  125    4×M16 180  240  141  150  23 
G 25 50  40  335  115  220  222  125    4×M16 180  240  141  150  23 
G 40 50  40  335  115  220  222  125    4×M16 180  240  141  150  23 
G 65 50  40  335  115  220  222  125    4×M16 180  240  141  150  23 
G 100 80  - 435  165  272  222  160    8×M¹6 180  290  141  240(230) 34 
G 160 80  100  469  189  280  278  160    8×M16 220  298  172  241  64 
G250 100  80  529  219  310  278  180    8×M16 220  328  172  241  72 

Honeywell Elster-Instromet RVG Flange Connection G16 – G400 and RVG-ST Standard Thread Connection G10 – G25 Rotary Gas Meters
Minimum wall clearance:Mor N in mm
  M N N
with HF pulser
G16-G65 120  190  250 
G100 170  240  300 
G160 200  245  310 
G250 230  285  340 
G400 305  350  435 




Technical data RVG-ST
Size G10 G16 G25
Qmin (m3/h) 0.8  0.8  0.8 
Qmax (m3/h) 16  25  40 
Rangeability 1 : 20 1 : 20 to 1 : 30 1 : 20 to 1 : 50
Flow range 0.8 - 40 m3/h
Start-up flow rate 0.03 m3/h (0.5 l/min)
Gas temperature -20 °C to +60 °C
Ambient temperature -20 °C to +70 °C
Line pressure (gauge) Maximum 20 bar
Protection class IP67 (suitable for outdoor installation)
Housing Aluminium; pistons made of aluminium
Metrological approval PTB
ATEX approval Ex-Zone 1
Media Natural gas, inert gases
Max. error:
± 1 % for Qt - Qmax
± 2 % for Q min - Qt
Qt = 0.2     Qmax, for measuring range ≤ 1:20
Qt = 0.15   Qmax, for measuring range > 1:30
Qt = 0.1     Qmax, for measuring range = 1:50
Qt = 0.05  Qmax, for measuring range > 1:50
Applied standards EN 12480, DIN EN 13463-1 and -5, EN 50020:2002
Index 8-digit roller index, reading from the front
Outputs LF Reed contact E1
 -  Standard: 1 contact   (pulse value = 10 pulses/m3) + PCM*
 -   Option:     2 contacts (pulse value = 10 pulses/m3) + PCM*
HF pulser (option)
 -   1 HF pulser (pulse value = 2500 pulses/m³) according to DIN EN 50227 (Namur)
     Equipment: 1 HF-pulser + 1 LF-reed contact + PCM*
Pressure/temperature tapping 2 pressure tappings ¼" NPT, 2 thermowells applicable
Pipe connection -   Pipe thread ISO 228, G 1 ½ (internal thread),
     adaptable to pipes DN 25 (1"); DN 32 (1 ¼"); DN 40 (1 ½"), DN 50 (2")
-   Flanged connection DN 25, DN 32, DN 40, DN 50 according to DIN 2633 and ASME B16.5
Mounting Horizontal or vertikal
Flow direction Left → right; right → left; top → bottom; bottom → top
must be specified in the order
Weight (kg) 4.5 
* PCM: supervision contact against tampering
 
Honeywell Elster-Instromet RVG Flange Connection G16 – G400 and RVG-ST Standard Thread Connection G10 – G25 Rotary Gas Meters
Optional available are connecting sets consist of:
3 x gasket
1 x sieve
2 x adapter piece
2 x union nut
for 1" pipes with outside thread No. 730 176 52
for 1¼" pipes with outside thread No. 730 176 53
for 1½" pipes with outside thread No. 730 176 54
for 2 " pipes with outside thread No. 730 181 60

 
 
Honeywell Elster-Instromet RVG Flange Connection G16 – G400 and RVG-ST Standard Thread Connection G10 – G25 Rotary Gas Meters
Honeywell Elster-Instromet RVG Flange Connection G16 – G400 and RVG-ST Standard Thread Connection G10 – G25 Rotary Gas Meters
Honeywell Elster-Instromet RVG Flange Connection G16 – G400 and RVG-ST Standard Thread Connection G10 – G25 Rotary Gas Meters


 
Honeywell Elster-Instromet RVG Flange Connection G16 – G400 and RVG-ST Standard Thread Connection G10 – G25 Rotary Gas Meters
Honeywell Elster-Instromet RVG Flange Connection G16 – G400 and RVG-ST Standard Thread Connection G10 – G25 Rotary Gas Meters
Honeywell Elster-Instromet RVG Flange Connection G16 – G400 and RVG-ST Standard Thread Connection G10 – G25 Rotary Gas Meters
 
Honeywell Elster-Instromet RVG Flange Connection G16 – G400 and RVG-ST Standard Thread Connection G10 – G25 Rotary Gas Meters
Honeywell Elster-Instromet RVG Flange Connection G16 – G400 and RVG-ST Standard Thread Connection G10 – G25 Rotary Gas Meters
Honeywell Elster-Instromet RVG Flange Connection G16 – G400 and RVG-ST Standard Thread Connection G10 – G25 Rotary Gas Meters
 
Honeywell Elster-Instromet RVG Flange Connection G16 – G400 and RVG-ST Standard Thread Connection G10 – G25 Rotary Gas Meters
Honeywell Elster-Instromet RVG Flange Connection G16 – G400 and RVG-ST Standard Thread Connection G10 – G25 Rotary Gas Meters
Honeywell Elster-Instromet RVG Flange Connection G16 – G400 and RVG-ST Standard Thread Connection G10 – G25 Rotary Gas Meters

https://bnsens.en.made-in-china.com/product-group/bopTdXVcfIWz/Gas-Sensor-and-Flame-Detector-catalog-1.html?pv_id=1ild1lmn8e43&faw_id=null
 
Honeywell Elster-Instromet RVG Flange Connection G16 – G400 and RVG-ST Standard Thread Connection G10 – G25 Rotary Gas Meters
Honeywell Elster-Instromet RVG Flange Connection G16 – G400 and RVG-ST Standard Thread Connection G10 – G25 Rotary Gas Meters
Honeywell Elster-Instromet RVG Flange Connection G16 – G400 and RVG-ST Standard Thread Connection G10 – G25 Rotary Gas Meters

BNSENS (Nanjing) Sensor Technology Co., Ltd. is located in Nanjing, China. It is a high-tech enterprise specializing in the development, manufacturing and trade of sensor products. The company has brought together a group of outstanding technical experts in various fields such as automation, electronics, machinery and computers. All employees of the company have college degrees or above. It adopts the world-class management and operation model and 6 sigma quality system. At present, the company's main products are pressure, liquid level, flow, current, switches, etc. The company's users are all over the country, and some products have been exported to Japan, South Korea and Southeast Asia.

Since its inception, the company has been based on the technical accumulation and management standards of American sensor giants. It is composed of senior engineers and managers who have served in multinational companies for many years, and has rapidly developed various pressure sensors, transmitters, liquid level, flow meters, pressure switches, digital meters, current sensors, proximity switches and other products. After years of unremitting efforts, it has become one of the leading suppliers in the domestic automation industry. Our pressure transmitters can achieve an accuracy of more than 3/10, 000. The products have been widely used in oil, natural gas, electricity, chemical industry, metallurgy, building materials, food, light industry, environmental protection, aerospace, tap water, municipal and other industries.

It is a sensor science and technology innovation company that masters the core technology of MEMS chips. The company has a research and development center in Minnesota, USA. The leader is Dr. Pan Hanjin, a famous scientist in the sensor industry. Dr. Pan Hanjin has been deeply involved in the sensor industry for more than 20 years and is an expert in the sensor industry.

The company has a number of ASIC chips independently developed, which are widely used in industrial, automotive, home appliance and other markets.

BNSENS (Nanjing) Sensing Technology Co., Ltd. is a strategic partner of Honeywell in China. The two parties proposed a plan of East serving East and jointly developed several sensors specifically for the Chinese market. These sensors will be widely used in intelligent manufacturing, Internet of Things, artificial intelligence, and smart home fields. These sensors include: Magnetic sensors, temperature sensors, humidity sensors, force sensors, fire water pressure sensors, equipment vibration sensors, human body status monitoring sensors, motion sensors, etc.

History of BNSENS Company:

BNSENS is a company focusing on sensors, instruments, and electronic components. We are a young company, founded in 1999, just 25 years old, and we are still growing.

1999: The company's first pressure sensor was launched, mainly for the petroleum and petrochemical industries.

2002: The company expanded its product line and launched temperature sensors

2005: Started producing high-precision pressure sensors for the test and measurement market

2006: Became an official authorized agent of Honeywell

2009: Introduced the Six Sigma management system, and the product qualification rate was greatly improved

2010: Became a supplier of Emerson

2011: We started selling SICK sensors

2014: Introduced the sensor production line from Germany, developed more industrial control sensors, and cooperated with TSMC

2015: Cooperated with Siemens in Vietnam

2017: The factory moved to Nanjing High-tech Zone

2019: Became a national high-tech enterprise in China

2023: We started selling products from Infineon and Rohm

BNSENS, The Future Starts Here.

  
Honeywell Elster-Instromet RVG Flange Connection G16 – G400 and RVG-ST Standard Thread Connection G10 – G25 Rotary Gas Meters
Honeywell Elster-Instromet RVG Flange Connection G16 – G400 and RVG-ST Standard Thread Connection G10 – G25 Rotary Gas Meters
Honeywell Elster-Instromet RVG Flange Connection G16 – G400 and RVG-ST Standard Thread Connection G10 – G25 Rotary Gas Meters
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Send Inquiry
Chat Now